Submittal Sheet

2/2 DES.D.410.L1.22 January 2017
Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products already
on order provided that such alterations can be made without subsequential changes being necessary to specications already agreed. All trademarks in this material are the property of the respective
companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved. www.secop.com
ASHRAE LBP 115V, 60Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 245 340 431 477 654 875 974 1135 1445 1793 1835 1987
Power cons. in W 90 108 121 127 148 172 182 197 225 254 257 270
Current cons. in A 1.88 1.94 1.99 2.02 2.12 2.25 2.31 2.41 2.60 2.83 2.86 2.96
EER in BTU/Wh 2.72 3.16 3.56 3.75 4.40 5.09 5.36 5.76 6.43 7.06 7.14 7.37
EN 12900 Household (CECOMAF) 115V, 60Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 58 80 102 113 155 208 231 269 343 425 435 471
Power cons. in W 90 108 121 127 148 172 182 197 225 254 258 270
Current cons. in A 1.88 1.94 1.99 2.02 2.12 2.25 2.31 2.41 2.60 2.83 2.86 2.96
COP in W/W 0.64 0.75 0.84 0.89 1.04 1.21 1.27 1.37 1.52 1.67 1.69 1.74
Accessories for TFS4.5FT Figure Code number Test conditions
ASHRAE
LBP
EN 12900/
CECOMAF
Starting relay (protector incl.)
a2
(pos.1)
117U4113 Condensing temp. 130°F 131°F
Protector 3/4 in. Texas Instruments MRP39AIL-6 Ambient temp. 90°F 90°F
Starting relay (protector incl.)
a2
(pos.2)
c
117U4126 Suction gas temp. 90°F 90°F
Protector 3/4 in. Texas Instruments MRP39AIL-6 Liquid temperature 90°F 131°F
Start. capacitor 320 µF 117U5022
Cover b 117U1021 Mounting accessories Code number
Cord relief d 117U0349 Bolt joint for one comp. Ø: 5/8 in. 118-1917
Cord relief capacitor dc 117U0349 Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919