Submittal Sheet
January 2017 DES.D.410.L1.22 1/2
TFS4.5FT
Tropical Compressor
R134a
115-127V 60Hz
General
Code number 102G3426
Approvals UL984
Compressors on pallet 125
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F – -31 to 45
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 140 (158)
Max. winding temperature continuous (short) °F – 257 (257)
Cooling requirements
Frequency Hz 50 60
Application
LBP MBP HBP LBP MBP HBP
90°F – – – F
1
F
1
–
100°F – – – F
1
F
1
–
110°F – – – F
1
F
1
–
Remarks on application: In capillary tube systems where non-equalized pressures may
occur at compressor start, or in areas with short power supply drop-outs, a starting
capacitor can be used for ensuring a successful start (CSIR).
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A – 20.1
Cut in Current, HST | LST A – 20.1
Resistance, main | start winding (77°F) Ω 3.3 8.8
Design
Displacement cu.in 0.29
Oil quantity (type) .oz. 9.5 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 57.3
Weight without electrical equipment lbs. 14.9
Dimensions
Height inch A 6.81
B 6.65
B1 –
B2 –
Suction connector location, I.D. in. | angle C 0.252-0.259 | 30°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 31.5°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.202-0.205 | 28°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
S = Static cooling normally sufcient
O = Oil cooling
F
1
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F
2
= Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area