Submittal Sheet
Dec 2011 Manufactured by Secop for Danfoss - DEHC.402.Q2.22 / 520N0282 1/2
SC18CLX.2
LBP Compressor
R404A/R507
115V 60Hz
General
Code number 104L2198
Approvals UL984
Compressors on pallet 60
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °F – -49 to 14
Voltage range V – 103 - 127
Max. condensing temperature continuous (short) °F – 131 (140)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
LBP MBP HBP LBP MBP HBP
90°F – – – F
2
– –
100°F – – – F
2
– –
110°F – – – F
2
– –
Remarks on application:
Motor
Motor type CSR
LRA (rated after 4 sec. UL984), HST | LST A 63.0 –
Cut in Current, HST | LST A 63.0 –
Resistance, main | start winding (77°F) Ω 0.6 3.2
Design
Displacement cu.in 1.08
Oil quantity (type) .oz. 20.3 (polyolester)
Maximum refrigerant charge oz. 45.5
Free gas volume in compressor .oz. 49.4
Weight without electrical equipment lbs. 30.9
Dimensions
Height inch A 8.62
B 8.39
B1 7.60
B2 4.33
Suction connector location, I.D. in. | angle C 0.378-0.385 | 37°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks: Large Fusite®
S = Static cooling normally sufcient
O = Oil cooling
F
1
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F
2
= Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area