Submittal Sheet

ASHRAE LBP 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 35 517 1095 1738 2237 2466 3299 4260 4685
Power cons. in W 161 291 417 530 604 634 735 837 879
Current cons. in A 5.04 5.44 5.96 6.54 7.00 7.20 7.93 8.73 9.07
EER in BTU/Wh 0.21 1.78 2.62 3.28 3.71 3.89 4.49 5.09 5.33
ASHRAE LBP* 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 481 898 1420 2020 2496 2716 3525 4464 4880
Power cons. in W 258 353 448 534 593 618 705 799 840
Current cons. in A 5.41 5.70 6.10 6.57 6.94 7.11 7.72 8.41 8.70
EER in BTU/Wh 1.86 2.54 3.17 3.78 4.21 4.39 5.00 5.59 5.81
EN 12900 Household (CECOMAF)* 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 363 731 1188 1711 2123 2314 3011 3819 4176
Power cons. in W 245 346 444 535 595 621 709 804 845
Current cons. in A 5.35 5.66 6.08 6.57 6.95 7.12 7.76 8.46 8.76
EER in BTU/Wh 1.48 2.11 2.67 3.20 3.57 3.72 4.24 4.75 4.94
Accessories for SC12CLX.2 Figure Code
number
Test conditions
ASHRAE
LBP
ASHRAE
LBP*
EN 12900/
CECOMAF*
PTC starting device 1/4 in. spade connect.
Condensing temp. 130°F 110°F 113°F
3/16 in. spade connect. Ambient temperature 90°F 90°F 90°F
Starting relay 1/4 in. spade connect. a2 117U6020 Suction gas temp. 90°F 90°F 90°F
Cover b 103N2008 Liquid temperature 90°F 90°F no subcooling
Start. capacitor 240 µF 1/4 in. spade connect. c 117U5023
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC Bolt joint for one comp. Ø: 5/8 in. 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
Danf
oss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order pro
vided that such alterations can be made without subsequential changes being necessary eady agreed.
All trademarks in this material are property of the respec
tive companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 |© Danfoss | DCS (CC) | 2017.04 DEHC.ED.200.F1.02