Submittal Sheet

2/2 DES.D.461.J3.02 October 2018
Secop accepts no responsibility for possible errors in catalogs, brochures, and other printed material. Secop reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary to specications already agreed. All trademarks in this material are the property of the
respective companies. Secop and the Secop logotype are trademarks of Secop GmbH. All rights reserved. www.secop.com
Accessories for SC12CL Figure Code number Test conditions
EN 12900/CECOMAF
ASHRAE LBP*
PTC starting device 6.3 mm spade connectors
a1
Condensing temperature 45°C 43.3°C
4.8 mm spade connectors Ambient temperature 32°C 32°C
Starting relay 6.3 mm spade connectors a2 117U6005 Suction gas temperature 32°C 32°C
Cover b 103N2009 Liquid temperature no subcooling 32°C
Start. capacitor 80 µF 6.3 mm spade connectors c 117U5017
Cord relief d 103N1004 Mounting accessories Code number
Protection screen for PTC g Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 58 140 237 353 490 541 650 835 1048 1205 1292
Power cons. in W 190 253 316 380 445 468 512 581 654 704 730
Current cons. in A 2.15 2.27 2.43 2.61 2.82 2.90 3.06 3.34 3.64 3.85 3.97
COP in W/W 0.30 0.55 0.75 0.93 1.10 1.16 1.27 1.44 1.60 1.71 1.77
ASHRAE LBP* 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W
67
162 275 410 568 629 754 971 1220 1404 1505
Power cons. in W
190
253 316 380 445 468 512 581 654 704 730
Current cons. in A
2.15
2.27 2.43 2.61 2.82 2.90 3.06 3.34 3.64 3.85 3.97
COP in W/W
0.35
0.64 0.87 1.08 1.28 1.34 1.47 1.67 1.87 2.00 2.06