Submittal Sheet

Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.401.T2.22 / 520N0170 1/2
SC10CL
LBP/MBP Compressor
R404A/R507
115V 60Hz
General
Code number 104L1503
Approvals UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -40 to 45
Voltage range V 103 - 127
Max. condensing temperature continuous (short) °F 131 (140)
Max. winding temperature continuous (short) °F 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
LBP MBP HBP LBP MBP HBP
90°F F
2
F
2
100°F F
2
F
2
110°F F
2
F
2
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 41.9
Cut in Current, HST | LST A 41.9
Resistance, main | start winding (77°F) 1.0 4.3
Design
Displacement cu.in 0.63
Oil quantity (type) .oz. 18.6 (polyolester)
Maximum refrigerant charge oz. 45.8
Free gas volume in compressor .oz. 51.1
Weight without electrical equipment lbs. 27.7
Dimensions
Height inch A 8.23
B 8.00
B1 7.20
B2 3.93
Suction connector location, I.D. in. | angle C 0.320-0.327 | 37°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 37°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
S = Static cooling normally sufcient
O = Oil cooling
F
1
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F
2
= Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
= not applicable in this area

Summary of content (2 pages)