8226
10
12
11
13
14
M
a2
Main winding
Motor protector
Start winding
Thermostat
a2
d
d
c
b
c
c
Accessories for NF7CLX Figure Code number Test conditions
ASHRAE LBP*
ASHRAE MBP
EN 12900/CECOMAF
Starting relay 1/4 in. spade connect.
a2
117U4129 Condensing temp. 110°F 130°F 113°F
Protector 3/4 in. Texas Instruments MRT22AFZ-6 Ambient temperature
90°F 95°F 90°F
Cover (standard)
b
d
dc
(pos.1)
117U1021 Suction gas temp. 90°F 95°F 90°F
Cord relief
117U0349 Liquid temperature 90°F 115°F no subcooling
Cord relief capacitor
117U0349
Cover (alternative)
b
(pos.2)
117U1024
Mounting accessories Code number
with terminal board Bolt joint for one comp. Ø: 5/8 in.
118-1917
Start. capacitor 320 µF 1/4 in. spade connect.
c 117U5022 Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in.
118-1919
ASHRAE LBP* 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h
457 672 959 1304 1585 1716 2205 2780 3037 3451 4226 5117 5213 5609
Power cons. in W
191 229 271 313 343 356 401 448 468 499 555 616 622 649
Current cons. in A
3.65 3.76 3.93 4.14 4.32 4.40 4.71 5.07 5.22 5.47 5.93 6.43 6.48 6.70
EER in BTU/Wh
2.39 2.93 3.54 4.17 4.62 4.82 5.51 6.21 6.49 6.91 7.62 8.31 8.38 8.65
ASHRAE MBP 115V, 60Hz, fan cooling
F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h
280 456 690 974 1207 1316 1727 2214 2433 2789 3460 4237 4321 4669
Power cons. in W
176 221 270 318 353 368 419 472 494 529 590 656 663 691
Current cons. in A
3.60 3.75 3.96 4.22 4.43 4.53 4.88 5.29 5.46 5.74 6.24 6.78 6.84 7.07
EER in BTU/Wh
1.59 2.06 2.56 3.06 3.42 3.58 4.12 4.69 4.92 5.27 5.86 6.46 6.52 6.75
EN 12900 Household (CECOMAF) 115V, 60Hz, fan cooling F
2
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h
379 565 813 1111 1353 1467 1888 2384 2604 2960 3626 4389 4471 4809
Power cons. in W
189 229 271 314 345 358 404 452 473 504 561 623 629 656
Current cons. in A
3.64 3.76 3.93 4.15 4.33 4.42 4.74 5.10 5.26 5.51 5.97 6.48 6.54 6.76
EER in BTU/Wh
2.00 2.47 3.00 3.53 3.92 4.09 4.67 5.27 5.51 5.87 6.46 7.05 7.10 7.33
8408
M
10
5
4
3
2
1
L
N
7
8
6
12
14
13
11
Main winding
Start winding
Motor protector
a2
b
a2
c
c