Submittal Sheet
April 2019 DES.D.462.J3.22 1/2
NF5.5CLX
LBP/MBP Compressor
R404A/R507
115V 60Hz
General
Code number 105F1621
Approvals UL984
Compressors on pallet 80
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F – -49 to 45
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 122 (140)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
LBP MBP HBP LBP MBP HBP
90°F – – – F
2
F
2
–
100°F – – – F
2
F
2
–
110°F – – – F
2
F
2
–
Remarks on application: MBP 108 - 135V, 60Hz
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 30.0 –
Cut in Current, HST | LST A 30.0 –
Resistance, main | start winding (77°F) Ω 1.9 6.6
Design
Displacement cu.in 0.37
Oil quantity (type) .oz. 10.14 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 76.9
Weight without electrical equipment lbs. 22.2
Dimensions
Height inch A 8.00
B 7.76
B1 –
B2 –
Suction connector location, I.D. in. | angle C 0.320-0.327 | 15°
material | comment Copper | Rubber plug
Process connector location, I.D. in. | angle D 0.252-0.259 | 25°
material | comment Copper | Rubber plug
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 35°
material | comment Copper | Rubber plug
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
S = Static cooling normally sufcient
O = Oil cooling
F
1
= Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F
2
= Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
– = not applicable in this area