Air Cleaner User Manual

8
1 Make sure that the unit is wired properly and
is turned on
.
2 Check the on/off switch to make sure it is
on.
3 If the lamp is still not on, switch the unit
off, disconnect power and check the fuse.
4 Make sure the lamp is not broken and that
it is in the socket.
5 If the lamp is still not on, check the
ballast .
Replacement Parts
1 Ballast 240 vac (1002KCS) 1053
1 Ballast 120/277 vac 1651C
2 Interlock Switch 1050
3 On/Off Switch 120 V 1061
On/Off switch 240 V 1057
4 Fuse Assembly 1054
5 Fuse 1055
6 Power Cord 1124
7 Lamp Connector 1014
8 9 “ Split Lamp 1000KCS 1068
9 9 “ Straight Lamp 1000KCS 1068A
10 Brass lamp holder 1013
11 Sight Glass 1078
12 18 “ Lamp 1002kcs 1067
1002KCS
For the 240 vac units 1002kcs the ballast
resistance should be tested like before.
Disconnect power. For the 240 vac ballast
(#SS2060446) the resistance should be 14-
25 ohms. If below 14 ohms replace the bal-
last.
If everything else has been checked and
is fine, but the lamp is still out, the
ballast starter is blown and the ballast
should be replaced.
1000KCS units
1 Make sure that the unit is wired or
plugged into a 120 -277 vac feed that
is always on.
2 Check the on/off switch to make sure
it is on.
3 If the lamp is still not on, switch the
unit off and check the fuse.
4 Make sure the lamp is not broken and
that it is in the socket.
5 If the lamp is still not on the ballast of
the 1000KCS unit is not working, call
for replacement.