Instruction manual

6
1 Remove duct work in area you are going to
install. (Fig.4)
2 Remove the Second Wind Air Purifier from
carton and remove plastic wrap from around
the lamp prior to lighting. Remove front door
and filter.Attach to installation area of the duct
with self tapping screws. (Fig.5)
3 Install new duct work to existing duct work
and 9000 series unit. (Fig.6-7).
4 Seal the seams with mastic or tape.
5 Reinstall the filter and the front cover of the
unit.
6 Plug the cord into a 110 volt outlet (Fig.8)
7 The air purifier is designed to remain on
continuously. (Fig.12) If lamp does not
illuminate, see the troubleshooting section.
Installation should be done by a qualified HVAC contractor.
Read all safety instructions at the beginning of this manual.
Units should not be installed with in 12-18 inches of any non UV resistant materials. If ma-
terials are in question call manufacturer of said products to see if they are made with UV
inhibitors. Prolonged UV exposure will degrade non UV resistant materials. Non UV resis-
tant materials must be shaded or covered .
1 Marker
2 Tinsnips
3 Drill
4 Drill Bits
5 5/16” &
11/32 “Nut
driver
6 Tape
Measure
7 Duct work