Revision Level: 02 1 Revision Date: 02/16/2012
WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY 1 2 3 4 5 6 7 8 Read instruction manual before operating the units. Eye damage may result from directly viewing the light produced by these lamps. To reduce the risk of exposure to UV radiation, take UV-radiation protective measures for personnel during servicing.
PAGE Safety & Installation Concerns Unpacking Installation Locations Installation 20 x 25 or 16 x 25 Lamp Replacement Troubleshooting Replacements Parts 9000 & 9016 Cut Sheet Warranty 2 3 4 5 6 7 7 8-9 10-11 Your new Second Wind Air Purifier is shipped complete in one container. Carefully unpack the unit and all loose items from the shipping container. Fig. 2 illustrate the unit and all loose items packed with the unit.
RETURN FURNACE MODEL 9000 9000 9000 9000 The Second Wind Air Purifier has been tested effective in the destruction and reduction of bacteria, viruses and fungus under various conditions. The effectiveness of this device may vary depending upon room area and rate of circulation. The health aspects associated with this product and its ability to aid in disinfection of environmental air were not investigated by Underwriters Laboratories Inc. (UL) TO DETERMINE AN INSTALLATION LOCATION SEE: FIG.
• • • Installation should be done by a qualified HVAC contractor. Read all safety instructions at the beginning of this manual. CAUTION: Equipment Damage Hazard. Ultraviolet light can cause color shift or surface degradation and sometimes-structural degradation of non-metallic components. Select mounting location that prevents exposure to plastic flexible duct components, polyurethane foam insulation material, rubber hoses, wire insulation, etc.
Second Wind Air Purifier lamps are designed to be on all the time. After approximately 9000-11000 hours of operation the lamps intensity will decrease. Installation of a replacement lamp is best handled by a HVAC Contractor. 1 Turn unit off and unplug the power cord. Wait for the surface of the lamp to cool. 2 Remove Door. (Fig.9) Door 3 Remove Filter make sure lamp is off. (Fig.10) 4 Unsecure lamp from spring clip holder. (Fig.11) 5 Pull lamp out from socket. (Fig.
1 2 3 4 5 6 7 8 9 Make sure that the unit is plugged into an outlet that is always on. Check the on/off switch to make sure it is on. If the lamp is still not on, switch the unit off, unplug the power cord and check the fuse. Make sure the lamp is not broken and that it is in the socket. Check to see if pin on door is activating the interlock switch If the lamp is still not on check the ballast. Check the input power by testing the outlet for 120 VAC. Test the resistance of the ballast.
All Second Wind Air Purification systems that are attached to your Heating, Ventilation and Air Conditioning System (HVAC) have a Limited Lifetime unit, Lifetime ballast warranty. The lamps for all the HVAC attached units have a (1) year warranty.(MODELS:9000,90002,9000-3,9016,9016-2,9016-3) ONE (1) YEAR COVERAGE LAMPS The lamps are warranted by Second Wind for a period of one (1) year from the date of the original installation, when installed and operated in accordance with Second Wind recommendations.
WARRANTY LIMITATIONS This warranty will be voided if the covered equipment (only second wind replacement parts or units are warranted) is removed from the original installation site. This warranty does not cover damage or defect resulting from: 1 Accident, neglect or unreasonable use or operation of the equipment, including operation of electrical equipment at voltages other than the range specified on the unit name plate.