Product Manual
21
Maintenance and Care
The user of this product is expected to follow all operating and safety
instructions of this manual and of the machinery operator's manual.
Perform periodic checks of the product's performance. The manufacturer or its
representatives assume no responsibility for results of the use of this product
including any direct, indirect, consequential damage, and loss of profits. Check
your work frequently.
Your laser receiver was shipped in a protective carrying case. If the unit is
transported from job to job inside its protective case and normal instrument
precautions are followed, the unit will provide many years of service.
Do not wipe dust or dirt off the laser receiver with a dry cloth as scratching could
occur, possibly damaging these surfaces. Use only a good quality glass cleaner
with a soft cloth on all external components. If these surfaces have
hardened
concrete or other materials on them, take the system to your
Authorized
Service Center for cleaning.
If the system will not be used for a 30 day period or more, it is recommended
to remove the batteries from the receiver. Store and transport the receiver in
its carrying case.
Refer to your state or local requirements for the disposal of batteries. Be sure
to dispose of all batteries properly.
20
Operation - Secondary Functions
Touch Panel Lock: Press and hold the power switch and then press the
accuracy switch to turn the touch panel lock function on and off. When on,
the lock symbol is displayed on the LCD. Switches cannot be changed
and accidental changes from dirt or debris knocking the switches are
prevented. To make changes to the unit, turn the switch panel lock off.
Communication Options: This function is not currently used on the
receiver.
Touch Panel
Lock On
Blade Tilt Display with RD15 Remote Display
Although there is no provision for displaying blade tilt on
the BULLSEYE 6 receiver, the function can be turned on
and off when used with an RD15 if the receiver has Version
5 software. Activation requires simultaneously pressing
the power switch, plumb switch, and deadband switch of
the receiver when it is on. When activated, the receiver's
outside green on-grade LED's will blink, the center green
LED will be on and the RD15 tilt display will become active.
The blade tilt deadband is fine, or ± 0.5°.
Repeat the three button procedure to turn the display off.
The receiver's outside green on-grade LED's will blink and
the center green LED will be off.
If the BE 6 has older Version 4 software, the tilt display will always be on.
Slope Matching: The blade tilt indicator can be set to zero or nulled at a blade
slope other than level. This is used for matching an existing slope or setting
the blade to a predetermined slope.
To set the blade tilt indicator at a slope other than level, position the blade at
the desired slope. Ensure the receiver is aligned properly side to side and front
to back with the blade. With the receiver on, simultaneously press and hold the
power switch and the plumb, deadband, and brightness switches. Continue
holding all four switches until a "0" symbol followed by a "Y" symbol is briefly
displayed. The blade slope is now nulled at the existing slope.
To reset the blade tilt indication back to level, position the blade to level and
check with a four-foot level or other method. Repeat the above calibration
procedure with the blade level.