Communication Protocol and Camera ID DIP Switch Setup: 
Before the Mini PTZ Camera is installed, first set up the DIP switches to configure the camera ID and the  
communications protocol. 
a 
Communication Protocol 
Camera ID 
On 
Value 
On 
Value 
1 
2 
3 
4 
5 
6 
7 
8 
1 
2 
4 
8 
16 
32 
64 
128 
1 
2 
3 
4 
5 
6 
7 
8 
1 
2 
4 
8 
16 
32 
64 
128 
2 
+ 
8 
= 
10 
Example: Camera ID=5 
Example: Camera ID=10 
4. Set the communication protocol  
(4- pin DIP switch): 
–  Set the proper protocol using Pin 1 and  
Pin 2 of the 4-pin DIP switch. 
–  The protocol for the camera must be 
identical to the protocol used by the DVR 
or pan/tilt controller. If not, the camera 
cannot be controlled by the controller. See 
the DVR or pan/tilt controller  
manual for protocol information. 
–  If the protocol of the camera is changed, 
the camera must be turned off and then 
turned back on for the change to take 
effect. 
–  The factory default protocol is  
"Pelco-D, 2400 bps." 
–  Pins 3 and 4 are set by the factory and 
must not be changed. If they 
are changed, 
the camera WILL NOT OPERATE 
PROPERLY. 
1 
+ 
4 
= 
5 
1. Remove the clear dome of the Mini PTZ Camera by turning it counterclockwise by hand. 
2. Look for the two DIP switch blocks 
near the base of the black plastic dome which surrounds the camera. DO   
  NOT REMOVE THE BLACK PLASTIC DOME. 
3. Set the camera ID (8- pin DIP switch): 
–  The camera ID is a binary number from 1 to 255. Factory default camera ID is "1."  
–  Do not use "00000000" as a camera ID. 
–  The ID number of a particular camera must match the Cam ID setting of the DVR or keyboard controller. 
DO NOT TOUCH 
PINS 3 AND 4 