SA-027HQ 365-Day Annual Timer Manual    Two N.O. or N.C.
ENFORCER 365-Day Annual Timer Table of Contents: Introduction ..................................................... 2 Features .......................................................... 2 Specifications .................................................. 3 Parts List ......................................................... 3 Overview ......................................................... 3 Installation ....................................................... 3 Function Buttons ..........................
ENFORCER 365-Day Annual Timer Specifications: Parts List: Input voltage Number of relays Relay rating Current draw Number of prog. events ON Blue LED OFF Number of prog.
ENFORCER 365-Day Annual Timer Relay Options: 1. Press the UP or DOWN button while the main screen is on to show the relay status screen. a. Press and hold the UP button for 3 seconds to toggle relay 1. b. Press and hold the DOWN button for 3 seconds to toggle relay 2. 2. See Table 2 below for different event modes available under Event programming Table 2: Event Modes Disable ON OFF Pulse Disables the event (factory default) Turns the relay ON Turns the relay OFF Activates the relay for 1~99 secs.
ENFORCER 365-Day Annual Timer Setting the Time and Date: 1. To set the time and date, press the SET button on the SA-027HQ until “ENTER TO SET TIME" appears on-screen. Press the ENTER button to confirm the programming selection. ENTER TO SET TIME 01/01/01 SU 01:01 05/22/09 SU 01:01 05/22/09 FR 01:01 05/01/01 SU 01:01 05/22/01 SU 01:01 05/22/09 FR 16:01 05/22/09 FR 16:20 2. Press the UP or DOWN button to enter the correct month, date, and year. 3.
ENFORCER 365-Day Annual Timer 6 SECO-LARM U.S.A., Inc.
ENFORCER 365-Day Annual Timer SECO-LARM U.S.A.
ENFORCER 365-Day Annual Timer Programming Holidays: 1. To set holidays for suspending normal operation of the timer, press the SET button on the SA-027HQ until “ENTER TO SET HOL” appears on screen. Press the ENTER button to confirm the programming selection. ENTER TO SET HOL #01 HOL 01/01/01 #05 HOL 07/04/09 2. Press the UP and DOWN buttons to enter the holiday number and the date the timer will suspend normal operation. Press the ENTER button to confirm the programming selection. 3.
ENFORCER 365-Day Annual Timer Programming Password: 1. To set the password, press the SET button on the SA-027HQ until “ENTER TO SET CODE” appears on-screen. Press the ENTER button to confirm the programming selection. ENTER TO SET CODE PASSWORD YES/NO PASSWORD CHNG Y/N ENTER PASSWORD OLD CODE 0000 THE FACTORY DEFAULT PASSWORD IS 0000. 2. Using the UP and DOWN buttons, select “YES” or “NO”. Press the “ENTER” button to confirm the selection. A confirmation screen will appear.
ENFORCER 365-Day Annual Timer Programming Menu Flowchart: 01/01/01 SU 01:01 Only if the password is enabled. See “Password Operation” on page 9. ENTER PASSWORD ENTER TO SET TIME ENTER TO SET EVNT ENTER TO SET HOL ENTER TO CLR MEMO ENTER TO SET BK ENTER TO SET CODE 10 SECO-LARM U.S.A., Inc.
ENFORCER 365-Day Annual Timer Using 2 Relays in Tandem: The SA-027HQ can be configured so that both relays operate at the same time. By setting the jumper to the “ON” position, the timer will output on both relays whenever an event is programmed for either Relay #1 or Relay #2 (factory default is set to OFF).
ENFORCER 365-Day Annual Timer Sample Application: Power supply 12~24 VAC/VDC Backup battery power input Backup battery First-person-in #1 Relay output #1 Gate operator N.O. (A gate operator connected to the lock relay output is triggered and opens a gate) COM N.C. First-person-in #2 Relay output #2 Bell N.O. COM N.C.