User Manual
ENFORCER VPD Combiners 
SECO-LARM U.S.A., Inc.  7 
Power Range: 
RJ45 Connections: 
Camera Connections: 
Video Connections: 
NOTE: A is channels 1~4, B is channels 5~8, C is channels 9~12, D is channels 13~16. 
Data Connections: 
Use this chart to determine the maximum distance between the VPD Combiner and the cameras 
when powering cameras at extended distances. 
Power Supply Voltage 
26VAC 
13VDC 
Resultant Camera Voltage 
20VAC 
10VDC 
100mA Camera 
1,960ft (600m) 
984ft (300m) 
300mA Camera 
656ft (200m) 
328ft (100m) 
500mA Camera 
394ft (120m) 
197ft (60m) 
1A Camera 
197ft (60m) 
98ft (30m) 
1  Video  +  White-Orange 
2  Video  -  Orange 
3  Data  +  White-Green 
4  Power -  Blue 
5  Power +  White-Blue 
6  Data  -  Green 
7  Power +  White-Brown 
8  Power -  Brown 
TIA/EIA-568B 
TIA/EIA-568B 
1  Ch 2  +  White-Orange 
2  Ch 2  -  Orange 
3  Ch 3  +  White-Green 
4  Ch 1  -  Blue 
5  Ch 1  +  White-Blue 
6  Ch 3  -  Green 
7  Ch 4  +  White-Brown 
8  Ch 4  -  Brown 
TIA/EIA-568B 
1  Data A+  White-Orange 
2  Data A -  Orange 
3  Data B+  White-Green 
4  Data C -  Blue 
5  Data C+  White-Blue 
6  Data B -  Green 
7  Data D+  White-Brown 
8  Data D -  Brown 
TIA/EIA-568B 
1  Data  +  White-Orange 
2  Data  -  Orange 
4-channel models: 