Spec Sheet

SECO
-
LARM
®
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Copyright © 2020 SECO-LARM U.S.A, Inc. All rights reserved.
All trademarks are the property of SECO-LARM U.S.A., Inc. or their respective owners.
The SECO-LARM policy is one of continual development. For that reason, SECO-LARM reserves the right to
change prices and specifications without notice. SECO-LARM is not responsible for misprints.
Phone: (949) 261-2999 | (800) 662-0800 Fax: (949) 261-7326
Website:
www.seco
-
Email:
sales@seco
-
larm.com
PI_EAP
-
1D1Q_200131.docx
Access Control Power Supply, Single Output
EAP
-
1D1Q
1 Output, 1A@12/24 VDC
EAP-1D1MQ
Power supply board only
Features:
Input 110~240 VAC, fused at 3.15A
Filtered and electronically regulated output
AC Input and DC output LED status indicators
Adjustable output voltage to compensate for
voltage drop
AC power failure supervision relay
Overcurrent fuse-protected AC input
Automatic shutdown for overcurrent / short-circuit
protection
12/24 VDC Outputs, field selectable
Battery failure / low battery supervision relay
Built-in back-up battery charger (Batteries not
included)
Automatically switch to backup battery if AC fails
Selectable 2.2k< End-of-Line (EOL) resistor for
AC
failure and battery failure supervision relays
Selectable delay timer (5sec, 5min, 5h) for AC
failure supervision relay via DIP switch
Specifications:
Operating voltage 110~240 VAC
Output voltage 12/24 VDC (selectable)
Output
voltage range
(adjustable)
12VDC 12~13
24VDC 23~25
LED Status
indicator
DC Red=12VDC output, blue=24VDC output
AC Green, input
Current rating
1A@12/24 VDC
Supervision relays
EOL: Selectable ON (2.2k<) or OFF,
3A@24VDC dry relay output
AC input fuse rating 3.15A
AC Power cord 6ft (1.8m)
Operating humidity 85% maximum
Operating temperature -4°~149° F (-20°~65° C)
Dimensions 7
3
/
4
"x10
1
/
16
"x3
9
/
16
" (197x225x91 mm)
Weight 4-lb 1.8-oz (1866g)
12/24
VDC
Heavy
Duty
Adjustable
Output
Voltage
Short
Circuit
Protection
Enclosure:
Heavy-duty steel case with removable cover for easy
access to connections
Ventilation holes to prevent heat buildup
Room for one 7Ah battery or two 4AH batteries
(Batteries not included)
Knockouts for power connections and optional cam lock
EAP
-
1D1Q shown