SEC SEC America, LLC Model 822 PS Pump Sentry Model 1622 PS Pump Sentry Owner's Manual Sept.
Index Page How Pump Sentry Works……………………………..…….. 3 Important Safety Instructions…………………………….... 4 Safety Warnings……………………………………………… 5 Battery Precautions………………………………………….. 6 Battery Box……………………………………………………. 8 Installation Location…………………………………………. 8 Making Connections…………………………………………. 9 Installation Test………………………………………………. 9 Changing the Battery………………………………………… 10 Charger Functions.
Pump Sentry Models 822 PS & 1622 PS INSTALLATION INSTRUCTIONS The Pump Sentry is an innovative power station designed to operate your pump during a power outage. When properly installed, it will provide many years of reliable service. To ensure that the Pump Sentry is optimally used and properly connected, we recommend its installation be made by a licensed electrician or fully qualified professional. Read these instructions completely and follow directions carefully.
While the Pump Sentry is a sophisticated electronic device, it should not be expected to perform beyond its limitations, and extreme care should be taken to insure safe operation within specifications. IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS – THIS MANUAL CONTAINS IMPORTANT INSTRUCTIONS FAILURE TO FOLLOW SAFETY INSTRUCTIONS AND WARNINGS COULD RESULT IN INJURY OR DEATH • Read all the instructions before installing or operating the Pump Sentry.
• Do Not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause electrical shock and/or fire hazard. WARNING: RISK OF ELECTRICAL SHOCK In the event of a short circuit, grounding reduces the risk of electrical shock by providing a safe path to ground. The Pump Sentry must be properly grounded. The Pump Sentry is equipped with a cord having a ground wire with an appropriate three pronged plug.
BATTERY PRECAUTIONS: WARNING: IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. 1. Servicing of batteries should be performed or supervised by a person knowledgeable anout batteries and the required precautions. Keep unauthorized personnel away from batteries. 2. When replacing batteries, use only models conforming to Battery Council International (BCI) 27 DC specifications for Group 27 Deep Cycle Marine batteries. At the time of this publication, the following model batteries are recommended.
B. If electrolyte comes in contact with the skin, wash if off immediately. C. If electrolyte comes in contact with the eyes, flush thoroughly with water and seek medical attention immediately. 6. CAUTION – Lead acid batteries can present a risk of fire and explosion because they generate hydrogen gases. The following precautions must be followed. A. Do Not smoke when near batteries. B. Do Not cause sparks or allow open flame in the battery area. C.
BATTERY BOX Your selected battery should be stored in a high quality plastic or nylon battery box with a lid that is designed for this purpose. LOCATION • In a typical installation, the Pump Sentry should be mounted on the wall, above the sump pit or crock, and in accordance with all applicable local electrical codes. • It should be in close proximity to a grounded AC outlet and the battery box (not closer than 2 feet). VENTILATION • Do Not block either the fan or the exit air ports of the Pump Sentry.
MAKING CONNECTIONS After mounting Pump Sentry to the wall, follow these steps. • Make sure the ON/OFF switch is in the OFF position. • Connect the red battery cable to the Red (Positive) + terminal of the Pump Sentry. • Connect the black battery cable to the Black (Negative) – terminal of the Pump Sentry. WARNING! DO NOT REVERSE THESE CONNECTIONS. DAMAGE TO THE PUMP SENTRY WILL OCCUR AND YOU WILL VOID THE WARRANTEE. WARNING! A spark may occur when connecting the second cable. This is normal.
battery and providing line power. CHANGING THE BATTERY If for any reason the battery needs changing, it is important to follow the steps below, in the order shown to avoid damage to the Pump Sentry unit. 1. Turn the ON/OFF switch on the Pump Sentry to the OFF position. 2. Unplug the input power cord of the Pump Sentry from the AC outlet. 3. Unplug the input power cord of the pump from the AC outlet on the Pump Sentry 4. Disconnect the batter cables from the batter.
Charger Function The smart charging system in Pump Sentry 822PS/1622PS is microprocessor controlled to yield optimum charging rates and long battery life. When the electrical source is restored allowing the resumption of the charging process, there is a 2 second delay during which the charge state of the battery is assessed. After this delay, at least one of the 4 LED indicators comprising the battery monitor will illuminate.
Figure #2 Figure #1 Charger Fuse F1 POWER OUTPUT F2 Active When Lit Main Fuse BATTERY MONITOR When Utility AC is Down ALL Battery Indicators Are OFF Replace Battery Fully Charged Trickle Charge High Charge Inverter ON/OFF SIDE VIEW TOP VIEW 12
How to Discern When Pump Sentry is Operational in the Backup Mode When all four LED’s of the battery monitor are OFF, and the pump sentry is plugged into an AC outlet, the unit is in the back up mode. In this mode when there is sufficient energy in the battery to operate the system, the uninterruptible power LED is illuminated. Once the battery is depleted the uninterruptible power light will extinguish, indicating an absence of AC power at the Pump Sentry’s output.
Pump Sentry 822 PS, 1622 PS Manufactured by SEC America, LLC S. Burlington, VT, 05403 Manufacturers Limited Warranty Pump Sentry is warranted to be free from defects in material and workmanship and to perform within applicable specifications for a period of two years after original shipment.