Technical Specifications
DC-DC LITHIUM IRON PHOSPHATE
(16 cell) BATTERY CHARGER
Design Features
- Pro
g
rammable Char
g
e Curve
- Low Input Voltage Cutout
- Compact design
- Convection and Forced Air Cooled
- Electronic Current Limiting
- Common Input/Output Negative Terminal
- Soft start technology
- Supplied with Cable Terminals
SPECIFICATIONS
SOURCE BATTERY SYSTEM VOLTAGE 24 VDC
NOMINAL INPUT VOLTAGE 25.5 VDC
INPUT VOLTAGE RANGE 22 to 32 (+/- 0.5) VDC
INPUT CURRENT AT MAX CONTINUOUS POWER 70 A
INPUT CURRENT AT NO LOAD (ON STATE) 0.36 A
INPUT CURRENT AT NO LOAD (OFF STATE) <0.012 A
MAX OUTPUT VOLTAGE
58.4 ( LiFePO4 Battery)
OUTPUT VOLTAGE REGULATION < 60 mV in constant voltage charging phase
MAX OUTPUT CURRENT
25 A
(during high charge portion of charge cycle)
OUTPUT POWER, CONTINUOUS (RESISTIVE LOAD) 1500 W
OUTPUT RIPPLE & NOISE <50 mV RMS
EFFICIENCY AT MAX CURRENT 92% @ max current, 26.4 V input (100% duty cycle)
LOW INPUT VOLTAGE SHUTDOWN factory set at 21.5V
LOW INPUT VOLTAGE RESET factory set at 23.5V
HIGH INPUT VOLTAGE SHUTDOWN > 34.0 VDC
OVERLOAD CURRENT LIMITING
OVER TEMPERATURE SHUTDOWN Yes (Auto reset)
INPUT-OUTPUT ISOLATION Input and Output Grounds are common
INPUT CONNECTION DIN Terminal Block
OUTPUT CONNECTION DIN Terminal Block
REMOTE CONTROL PORT
AMBIENT AIR OPERATING TEMPERATURE RANGE -40C to +50C
Derate 15% per 10C above 40C to a maximum of 60C
OPERATING HUMIDITY <95%, non condensing
ALTITUDE 6000 meters
Unit On/Off
High Charge Undervoltage Lockout
Float Charge Overload or Short Circuit
DIMENSIONS, INCHES (L x W x H) 17.8 x 6.9 x 3.6
MOUNTING CENTERS, INCHES 17.30 x 3.93
VIBRATION & SHOCK RESISTANT Internally Encapsulated
WEIGHT (LB/KG) 18.0 / 8.5
NOTE: Specifications are subject to change without notice.
YES - control terminal may be connected to 24V terminal
on control block via switch or relay or
may be connected to 24V via the ignition switch.
Model 7058 is designed to meet the emerging need to charge lithium 48V battery
banks from 24V systems. Model 7058 will output 25A @ 58V in full charge mode
and can be operated while load is drawn from the battery bank being charged. Off
the shelf units are ideal for use with lithium iron phosphate batteries. Model 7058
is microprocessor controlled and can be programmed at factory for operation with
other battery types.
ENVIRONMENT
MECHANICAL
PROTECTIONS
VISUAL
INDICATORS
Two Lights Operating in OFF/ON/FLASHING Modes
MODEL 7058
24V Source to 48V Battery; 25A
CONNECTIONS
OUTPUT
INPUT
Model 7058 may be factory programmed for Lithium batteries with other chemistries
Electronic vertical knee type at power limit with shutdown
requiring resit if voltage drops below 45V
SEC America, LLC
www.secamerica.com 1(802)8658388sales@secamerica.com