Consultation with SebaKMT User Manual GSM Transmitter Sebalog GT-3-S Mess- und Ortungstechnik Measuring and Locating Technologies Elektrizitätsnetze Power Networks Kommunikationsnetze Communication Networks Rohrleitungsnetze Water Networks Abwassernetze Sewer Systems Leitungsortung Line Locating Issue: Article number: 1 01 (04/2017) - EN 85837
Consultation with SebaKMT 2
Consultation with SebaKMT Consultation with SebaKMT The present system manual has been designed as an operating guide and for reference. It is meant to answer your questions and solve your problems in as fast and easy a way as possible. Please start with referring to this manual should any trouble occur. In doing so, make use of the table of contents and read the relevant paragraph with great attention. Furthermore, check all terminals and connections of the instruments involved.
Terms of Warranty Terms of Warranty SebaKMT accept responsibility for a claim under warranty brought forward by a customer for a product sold by SebaKMT under the terms stated below. SebaKMT warrant that at the time of delivery SebaKMT products are free from manufacturing or material defects which might considerably reduce their value or usability. This warranty does not apply to faults in the software supplied.
Terms of Warranty Contents Consultation with SebaKMT ...........................................................................................3 Terms of Warranty ...........................................................................................................4 1 Safety Instructions ...........................................................................................7 1.1 General Safety Instructions and Warnings.........................................................7 1.
Terms of Warranty 6.4.1 6.4.2 Installing loggers ..............................................................................................33 Installing GT-3-S ..............................................................................................33 6.5 Programming noise loggers (Log N-3) .............................................................34 6.6 Programming pressure loggers (Log P-3 / P-3 mini) .......................................35 6.
Safety Instructions 1 Safety Instructions 1.1 General Safety Instructions and Warnings Do not drop the device / the system’s components or subject it / them to strong impacts or mechanical shocks. • The limits described under Technical Data may not be exceeded. • The device / system must be in a technically perfect condition for measurement. • 1.2 General Notes Safety precautions This manual contains basic instructions for the commissioning and operation of the device / system.
Safety Instructions Special transportation The lithium batteries of the device are dangerous goods. The transport of the batteries requirements itselves and of devices which contain such batteries is subject to regulations based on the UN Model Regulations “Transport of Dangerous Goods” (ST/SG/AC.10-1). Please inform yourself about the transportation requirements and follow them when shipping the device. Electromagnetic This device is designed for industrial use.
Technical description 2 Technical description 2.1 Device design External features The GT-3-S has the following controls and external features: Element Description Cover plug with suspension ring Top cover ring Type plate with the device identification number (ID) Bottom cover ring Protective bracket GPS socket for aerial connection GSM socket for aerial connection On/Off contact field (magnetic switch) and status LED 1x red, 3x green Flashes blue Remains lit in blue Yellow, then red ... ... ... ...
Technical description Cover rings There is one “cover ring” at the top and bottom end of the GT-3-S respectively. These rings are screwed onto the housing by means of inside threads. They are used to secure the cover or the base of the device, and to seal the device tightly. The top cover ring may be opened to access the SIM card slot and the battery. NOTE The bottom cover ring must NEVER be opened. Otherwise, electronic components in the device may be damaged.
Technical description 2.3.1 LOG RI / LOG RI+ wireless interface for the computer LOG RI The “LOG RI” device is the compact, standard wireless interface for devices in the Sebalog series. LOG RI+ The “LOG RI+” wireless interface is available as an accessory from SebaKMT. In contrast to the LOG RI, the device has a more powerful wireless module that has a greater wireless range. Log RI Log RI+ Handling The LOG RI / LOG RI+ is easily connected to the computer using a USB port.
Technical description 2.4 Power supply The GT-3-S is supplied with energy by an internal lithium battery. The battery can be inserted and replaced by the user. Battery criteria The battery used must meet the following criteria: Parameter Value Type Size Quantity Rated voltage Capacitance Continual discharge current Lithium battery D cell 1 3.6 V min. 13 h min.
Technical description 2.5 Technical data The GT-3-S is distinguished by the following technical parameters: 2.6 Parameter Value Display Status LED Communication Short-range radio 913.02 MHz (US) 868 / 916 MHz (depending on country) Mobile network (913.02 MHz device): Dual band UMTS/HSDPA 850/1900 MHz Quad band GSM/GPRS/EDGE 850/900/1800/1900 MHz Mobile network (868 / 916 MHz device): Dual band UMTS/HSDPA 900/2100 MHz Quad band GSM/GPRS/EDGE 850/900/1800/1900 MHz Power supply 3.
Technical description 14
Inserting the SIM card / changing the battery 3 Inserting the SIM card / changing the battery The following is a description of the steps to carry out in order to • insert a SIM card in the device • replace a battery. The device must be opened to access the battery holder and the SIM card slot. NOTE The device contains sensitive semi-conductor components. Always proceed carefully in order not to damage any of the components. Do not use force.
Inserting the SIM card / changing the battery Step Description 4 Carefully pull the cover plug out of the housing. Result: You can now access the battery holder. Placing the GT-3-S on a table or another level surface is recommended at this point. The type plate should face upwards. 5 Hold the housing tight in one hand. Use your other hand to carefully pull the battery holder out of the housing, but only as far as the ribbon cable allows.
Inserting the SIM card / changing the battery Step Description When inserting the battery, make sure the polarity is correct. There are plus and minus symbols on the battery holder indicating this. 4 Reconnect the ribbon cable to the battery holder. Closing the housing In order to close the housing again, proceed as follows. again Step Description 1 Carefully push the battery holder back into the housing. Then push the ribbon cable into the housing.
Inserting the SIM card / changing the battery 18
Switching the GT-3-S on/off 4 Switching the GT-3-S on/off The GT-3-S features an internal magnet switch for switching it on and off. Move the supplied magnet over the On/Off contact field . The status LED lights up in red first; after the magnet is removed, it flashes in green three times. An LED regularly flashing in blue then indicates that the device is switched on and ready for data reception. To switch off the logger, hold the magnet on the On/Off contact field for a few seconds.
Switching the GT-3-S on/off 20
Preparatory work in the office 5 Preparatory work in the office 5.1 Mobile network, FTP server, e-mail account, etc. GSM / GPRS / UMTS For data transfer using the mobile network, a contract with a mobile service provider must be concluded. You will require a SIM card that is enabled for data traffic using GPRS / UMTS. FTP server You will require free memory on an FTP server to be able to upload measured data to it.
Preparatory work in the office 5.5 Saving access data for FTP server and e-mail account in the SebaDataView-3 software You must now save the access data for the FTP server used, along with the access data for the e-mail account you are using, in the SebaDataView-3 software configuration. This step is necessary to be able to download measured data from the FTP server and import it into the SDV-3 software at a later stage.
Preparatory work in the office 5.6 Registering devices in the SebaDataView-3 software 5.6.1 Introduction All GT-3-S and all loggers that are to be used for the upcoming measurement must have been registered in the SebaDataView-3 software. You can register the devices in the office, or do this directly on site. Important information Observe the following points: • All devices in the network (i.e. all GT-3-S used and all loggers) must be combined to form a shared zone.
Preparatory work in the office Step Description 3 Click New in the Zone segment. 4 In the window which opens, give the new zone a name and add a comment. Confirm the inputs using OK. Result: The new zone has now been created in the database and will appear in the directory tree. 5.6.3 Creating a group and adding a GT-3-S Creating a new group Create a new group in the directory tree. Step Description 1 Mark the zone under which the new group should be created. 2 Click New in the Group segment.
Preparatory work in the office Please remember: Only one GT-3-S can be registered per group. As soon as you wish to add an additional GT-3-S to the zone, you must start by creating a new group in this zone. The first GT-3-S in the zone should have already received a complete configuration before additional GT-3-S devices are added to the zone. All new GT-3-S will automatically copy the configuration data of the first GT-3-S in the zone. This considerably reduces the work required to program these devices.
Preparatory work in the office 5.7.2 Explanations for the GSM input window The figure shows the input mask for GSM configuration data. All parameters necessary for the mobile connection from / to the GT-3-S to function must be entered in it. (The data required can be found in your mobile phone contract, or ask your mobile operator for them.) GSM parameters You will find explanations for the individual items in the configuration window in the table.
Preparatory work in the office Segment Parameter Use the checkboxes to specify when the measured data should be uploaded: Every selected GSM day P Data will be uploaded every day (more exactly: on every “GSM day”). In case of leak P Data will only be uploaded if the leak threshold of a logger was exceeded during the last measurement. If no measured data are to be uploaded, deactivate both checkboxes.
Preparatory work in the office “Radio transmission Segment time” Radio settings Audio data Segment Miscellaneous settings Parameter Define when the GT-3-S and other devices connected should be responsive to outside transmissions by short-range radio. Use the checkboxes to select the required days of the week (socalled “Radio transmission days”). Use the two drop-down menus to select the transmission period for each transmission day.
Preparatory work in the office GPS function Segment Miscellaneous settings Theft alarm Segment Miscellaneous settings 5.8 Parameters Sync to GPS checkbox This checkbox allows you to define whether the GPS module for the GT-3-S is activated or deactivated for the upcoming measurement. When the checkbox is activated, the internal clock of the GT-3-S and the loggers connected can be synchronised with GPS time and the GPS position of the GT-3-S can be identified.
Preparatory work in the office Step Description The GT-3-S also sends a test e-mail or a test SMS to all recipients specified. The individual test steps are listed in the window on the screen. Successfully completed steps are marked with OK. An error message will appear if this is not the case.
GT-3-S activities performed at the installation site 6 GT-3-S activities performed at the installation site 6.1 Introduction After performing the set-up tasks in the office, all other steps must be performed directly at the usage site using a laptop. The following prerequisites must be met: • Laptop with SebaDataView-3 software • A wireless interface (e.g. LOG RI) must be connected to the laptop. • The loggers must be switched off. • All GT-3-S devices must be equipped with a SIM card.
GT-3-S activities performed at the installation site 6.3 Adding loggers to the GT-3-S group Introduction You have already created a GT-3-S group in the directory tree of the SDV-3 software. All loggers that are to be connected to the GT-3-S must now be added to this group. A maximum of three loggers per group is possible. Procedure Open the SDV-3 software on the laptop. Then proceed as follows: Step Description 1 Mark the relevant group in the directory tree.
GT-3-S activities performed at the installation site 6.4 Installing devices in the shaft 6.4.1 Installing loggers Install the logger/s in the GT-3-S group in the shaft. Detailed information on correct installation can be found in the operating manuals for the loggers. If you install an N-3 noise logger horizontally, make sure that the red marking on the logger points upwards. 6.4.2 Installing GT-3-S Make sure that the GT-3-S is switched on. The status LED flashes regularly in blue.
GT-3-S activities performed at the installation site 6.5 Programming noise loggers (Log N-3) This section is not relevant for Log P-3 / Log P-3 mini pressure loggers. Introduction When programming the GT-3-S in the office, you defined whether the device should send alarm messages in the event of an alarm or not. An alarm on an N-3 logger occurs when the lowest value recorded by the logger (minimum value) has reached or exceeded a specific threshold at the end of a measuring period.
GT-3-S activities performed at the installation site 6.6 Programming pressure loggers (Log P-3 / P-3 mini) This section is not relevant for Log N-3 noise loggers. Introduction When programming the GT-3-S in the office, you entered a number of measurement settings which apply for all loggers in the group in equal measure, such as the measurement days and the exact measurement period.
GT-3-S activities performed at the installation site 6.7 Sending the configuration to the GT-3-S Introduction This step involves sending the GT-3-S configuration data from the computer to the GT-3-S. You may have already performed this step during preparations in the office. This was necessary to be able to test whether the mobile connection functions there. This step must be repeated to ensure that the latest configuration data have been sent to the GT-3-S and the loggers.
GT-3-S activities performed at the installation site 6.8 Synchronising the GT-3-S with GPS This step involves synchronising the internal clock of the GT-3-S with GPS time. The GPS position of the device is also determined. This step is essential if you are working with N-3 noise loggers with measured data that are to be used for a correlation later on. Requirement The following prerequisites must be met: • The Sync to GPS option must be activated in the GT-3-S configuration.
GT-3-S activities performed at the installation site You can repeat this process at any time. To do so, mark the GT-3-S concerned in the directory tree of the SDV-3 and click on Link to logger in the menu bar. 6.10 Performing the GSM test and closing the shaft Now perform a GSM test to check whether the GT-3-S can connect to the mobile network properly at the usage site. Closing the shaft before the test is recommended to obtain a realistic result.
GT-3-S activities performed at the installation site Tento symbol indikuje, že výrobek nesoucí takovéto označení nelze likvidovat společně s běžným domovním odpadem. Jelikož se jedná o produkt obchodovaný mezi podnikatelskými subjekty (B2B), nelze jej likvidovat ani ve veřejných sběrných dvorech. Pokud se potřebujete tohoto výrobku zbavit, obraťte se na organizaci specializující se na likvidaci starých elektrických spotřebičů v blízkosti svého působiště.