6.2 Power supply
The Correlator is fitted with an internal rechargeable Li-ion battery. This can power the
devices for at least 16 hours. The battery’s present charge level is shown by the battery
symbol bottom right of the screen.
When the battery is low, a warning tone is heard and a warning message appears on
the screen. The device must be charged. Otherwise, it switches itself off automatically.
The Correlator is charged wirelessly in the C-3 transport case.
As soon as the device is situated at its storage place in the case, it is recharged via the
two pins , provided the case is connected to mains or a 12 Volt vehicle power
supply. The red indicator light is lit while the device is charging.
The Correlator is switched on during the entire charging process and can not be
deactivated. After the end of charging, the device remains switched on for the Auto-OFF
period specified in the system settings before it switches off.
Charging takes approximately 9 hours.
Heat is generated while charging. The charging station in the case therefore has a
temperature switch. The charger switches off automatically when it gets too warm inside
the case. It turns back on as soon as the degree of heat has fallen below a certain level.
NOTE
In order to prevent damage, observe the following precautions when
charging:
Use only the charging station in the transport case. Do not use other
chargers.
The ambient temperature should be between 10°C and 35°C
(50°F and 95°F).
To avoid heat accumulation, do not close the lid of the case at high
ambient temperatures during charging.
If you experience problems with the battery, please contact your
SebaKMT sales or service partner. Do not open the Correlator yourself.