Troubleshooting guide
DIAGNOSTIC TEST
The
control must
be
in the
OFF
state before
pressing
the touch-pad sequence
to start the test.
Starting the test mode
Close the door.
Select
the DRAIN/SPIN cycle.
Select NO
SPIN by
pressing
the
SPIN SELECT button five
(5)
times.
Push Prewash
Option button four
(4)times
within five
(5)
seconds. C:00
will
show
in the display.
lf
the Starting
procedure
fails,
push
PAUSE/CANCEL button. Then
repeat the starting sequence.
Test Program
Control
during Execution
To
advance to the
next
step of the
test
procedure, push
Prewash Option
button two
(2)
times.
Overview
Test Program
C:00
Door is Locked
Door
Lock System
C:01 Filling by cold
water inlet valve
Flowmeter, Cold water
inlet valve
C:O2 Distribution system
is
set to
Prewash
position
Dispenser motor,
Dispenser contact
C:03 Fill by
hot water inlet valve
Hot
water inlet valve
C:04 Drum rotates clockwise
at wash speed
Motor. CIM
control
C:05 Heater is switched ON.
Drum
rotates
clockwise
with wash speed.
lf there is not enough
water in
the
tub, the
water inlet valve will be switched ON to
fill-in
the
minimum water
quantity.
Heater. NTC
C:06 Drain
Pump is
ON
Drain
Pump
C:07 Drum rotates counterclockwise
from 35 to
90 rpm
within 15 seconds
Motor, CIM control
C:08 Drum rotates counterclockwise
with max. speed
Drum speed
>
1 100 rpm
Motor. CIM control
5-8