Use & Care Guide Manual Del Propietario Manuel Du Propri_taire Q Vacuum Cleaner Aspiradora Aspirateur Model, Modelo, 401.39030(U.S.) Modele 401.39035(U.S) CAUTION: Read and follow all safety and operating instructions before first use of this product. CUIDADO: Lea y sigue todas las instrucciones de operaci6n y seguridad antes del uso de este producto. ATTENTION Veuillez : life toutes les consignes de s6curite et le mode d'emploi avant d'utiliser ce produit. Sears, Roebuck www.sears.com and Co.
Before Using Your New Vacuum Cleaner ............................................ Vacuum Cleaner Care ............. 11-17 2 Kenmore Vacuum Cleaner Warranty ........................... 3 Important Safety Instructions ................................. Vacuum Cleaner Storage ............ 11 Dust Bin Removal and Replacement 12 Motor Filter Maintenance ............ 13 Exhaust Filter Maintenance ......... 14 4=5 Parts and Features ......................... 6 Assembly Instructions ...............
ONE YEAR LiMiTED WARRANTY ON KENMORE VACUUM CLEANER When installed, operated and maintained according to all instructions supplied with the product, if this appliance fails due to a defect in material and workmanship within one year from the date of purchase, return it to any Sears store, Sears Parts & Repair Service Center, or other Kenmore outlet for free repair. If this appliance is ever used for other than private family purposes, this warranty applies for only 90 days from the date of purchase.
WARNING Your safety is important to us. To reduce the risk of fire, electrical shock, injury to persons or damage when using your vacuum cleaner, follow basic safety precautions including the following: READ ALL INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING OR USING YOUR VACUUM CLEANER. Do not use outdoors or on wet surfaces. Electrical shock could Do not handle plug or appliance with wet hands. Do not put any objects into openings.
Usingimproper voltage mayresult indamage tothemotorand possible injurytotheuser.Proper voltage islistedonthecleaner plate. WARNING :Thecords,wires,and/ orcables supplied withthisproduct contains chemicals, including leadorleadcompounds, known tothestateofCalifornia tocause cancer andbirthdefects orother reproductive harm.Washhands afterusing. SAVE THESE INSTRUCTIONS Proper assembly and safe use of your vacuum cleaner are your responsibilities. Your vacuum cleaner is intended only for Household use.
it is important to know your vacuum cleaner's parts and features to assure its proper and safe use. Review these before using your vacuum cleaner. Item Accessories Part No.
Please pay special Z_ attention to these hazard alert boxes, and follow any instructions given. WARNING statements alert you tostatements such dangers fire,to electric shock, burns and personal injury. CAUTION alert asyou such dangerous personal injury and/or property damage. WARNING CAUTION Electrical Shock Hazard Do not overtighten. Do not plug into the electrical supply until the assembly is complete. Failure to do so could result in electrical shock or injury. Overtightening screw holes.
TOOL PLACEMENT c Place mini turbo brush (A)into the tool holder on side of the body. Place dust brush/upholstery tool (B) into its accessory holder on side of the body. Place crevice tool (C) into its accessory holder on side of the body. OPERATING INSTRUCTIONS 1. Turn the quick release upper cord wrap to either side and down to release the power cord. WARNING To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other).
Dust Bin Release Wand Release Brush Roll On/Off Power switch/Power Nozzle brushroll switch Circuit breaker The Power on/off button is located on the top of vacuum body. Turn on vacuum by power button after plugging cord into electrical outlet. The Power nozzle brush on/off button turns the rotating brushroll on and off. Turn brushroll switch on to clean carpet and rugs. Turn brushroll switch off to clean hard surface floors. The circuit breaker turns off the brushroll if its motion becomes obstructed.
,_::__i,__ i:_i_;;!i_ii_iiiii_i ! HANDLE RELEASE To release handle, push the handle release pedal located on the lower left side of the cleaner. A CLEANING TOOLS Rotate the handle and adjust it to the desired position for (A) storing the upright, (B) operating the cleaner, and (C) to clean under furniture. Attachment tools can be used to clean furniture, drapes, stairs, or in corners. Place the vacuum on the floor with handle in the upright position while using attachment tools.
Z CAUTION Brush agitator continues to rotate while hose is removed or in use and at all times while cleaner is on. Keep hair, loose clothing, fingers, and all parts of body away from brush area while cleaner is on. Cleaner must be in the upright position to lift the rotating brushroll off the carpet when cleaning above the floor. Simply push the attachment firmly onto the end of the wand or hose handle. To remove tool, twist and pull apart gently.
After cleaning out cyclone, ensure that cyclone cap is properly inserted and secured in place. Z WARNING Electrical Shock and Personal Injury Hazard Disconnect electrical supply before servicing or cleaning the unit. Failure to do so could result in electrical shock or personal injury from vacuum cleaner suddenly starting. EMPTY DUST BIN Turn cyclone cap to right until tab of cyclone cap fits into notch on rim of cyclone chamber. Push the dust bin release button.
Z WARNING filter Electrical Shock and Personal Injury Hazard Disconnect electrical supply before servicing or cleaning the unit. Failure to do so could result in electrical shock or personal injury from vacuum cleaner suddenly starting. Separate sponge filter and micro filter from filter case. Note : Inspect and clean motor filters on a regular basis. Based on frequent vacuum use, replace filters every 6 months for best vacuuming performance.
Note : Inspect HEPA filter regularly for accumulation of dust and debris. Replace if necessary. Based on frequent vacuum use, the HEPA exhaust filter should be replaced every 6 months for best vacuuming performance. 1. Remove Dust Bin and Motor Filter Case as previously described in this Use & Care Guide. 2. Grasp HEPA filter by one of the raised plastic fins and lift up and out. 3. Observe the order shown below when reassembling the filters.
TO REPLACE BELT OR BRUSHROLL Z_WARNING Electrical Shock and Personal Injury Hazard Disconnect electrical supply before servicing or cleaning the unit. Failure to do so could result in electrical shock or personal injury from vacuum cleaner suddenly starting. TO REMOVE BELT Slide belt onto motor shaft. Lay cleaner flat and flip cleaner to expose nozzle base. Base should lay flat and face up. To remove nozzle guard, remove 6 screws. Place new belt in area of brushroll without bristles.
DiverterPlunc Z WARNING Electrical Shock and Personal Injury Hazard Disconnect electrical supply before servicing or cleaning the unit. Failure to do so could result in electrical shock or personal injury from vacuum cleaner suddenly starting. 8. Depress the spring-loaded plunger to straighten the diverter hose to make it easier to clean out. If you notice a decrease in suction, you should inspect and clean out the small hose inside the Suction Diverter according to the following instructions. 1.
TO REPLACE BRUSHROLL TO REPLACE BELT 1. Slide the switch to the unlock position and remove bottom plate. 1. Remove bottom plate by sliding switch to unlock position. See figure in To Replace Brushroll instructions. 2. Loop one end of new belt around shaft of pulley. 2. Inspect condition of brushroll. Replace brushroll if brushes are worn down. To remove brushroll, pull up and out of end slots in nozzle housing. Insert ends of brushroll into same slots to replace.
Review this table to find do-it-yourself solutions for minor performance problems. Any service needed, other than maintenance described in this Use & Care Guide, should be performed by a Sears or other qualified service agent. Z_ WARNING Disconnect unit. Failure electrical supply before performing to do so could result in electrical I PROBLEM Cleaner I won't run Cleaner won't pick up or low suction. I POSSIBLE CAUSE 2. Blown house fuse or tripped house circuit breaker. 2.
Congratulations on making a smart purchase. Your new Kenmore product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance or repair from time to time. That's when having a Master Protection Agreement can save you money and aggravation. The Master Protection Agreement also helps extend the life of your new product.
Get it fixed, at your home or ours! Your For expert troubleshooting Home and home solutions m aNa g@ _ advice: horn@ www,managemyhorne.com For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it ! For the replacement parts, accessories and owner's manuals that you need to do-it-yourself. For Sears professional installation of home appliances and items like garage door openers and water heaters.