Specifications

440 01 1024 04
Specifications are subject to change without notice
31
Figure 26
Concentric Vent and Combustion
Air Roof Termination
Combustion
Air
Exhaust
36” Min
OR
36” Min
2” (50.8mm) Max
(914.4mm)
(914.4mm)
12 (304.8mm)
Min. Grade or
Snow Level
Figure 27
Concentric Vent and Combustion
Air Sidewall Termination
“A”
Vent
Dimension “A” is touching or 2 (50.4mm) maximum separation.
25-22-02dVent
Combustion Air
Exhaust
1 (25.4mm)
Maximum
Exhaust
“A”
“A”
Inlet
Figure 28
Sidewall Inlet Vent and Exhaust
Air Termination
Dimension “A” is touching or 2 (50.4mm) maximum separation.
8 Min.
18 (457.2mm) Min. for Cold Climates
[Sustained 0F(-17C) and below for
24 hours or more consecutive hours]
8 (457.2MM) Min.
20 (6.1m) Max.
12 (304.8mm) Min.
Grade or Snow Level
Exhaust
8 Min.
8 Min.
20 Max.
Figure 29
Sidewall Inlet Vent and ExhaustAir
Termination with Exterior Risers
18 Min. for Cold Climates
(Sustained temperatures 0 F
and below for 24 or more con
secutive hours)
Inlet
“A”
“A”
12 Min.
Grade or
Snow Level
Dimension “A” is touching or 2 (50.4mm) maximum separation.
Exhaust
Figure 30
Rooftop Inlet Vent and Exhaust
Air Termination
25-22-43
18 Min. for Cold Climates
(Sustained temperatures
0 F and below for 24 or
more consecutive hours)
Inlet
12 (304.8mm)
Min. Grade or
Snow Level
8 (203.2MM) Min.
20 (6.1) Max.
18 (457.2mm) Min. for Cold Climates
[Sustained 0F(-17C) and below for
24 hours or more consecutive hours]