User manual

Yukon HX Motherboard User Manual
3
Table 2. Memory Options for SIMM Sockets
For a total system
memory of
Install a SIMM of the
following size in both
sockets of Bank 1
Install a SIMM of the
following size in both
sockets of Bank 0
8 MB 4 MB (8 MB total in
bank 1)
Empty
16 MB 4 MB (8 MB total in
bank 1)
4 MB (8 MB total in
bank 0)
16 MB 8 MB (16 MB total in
bank 1)
Empty
32 MB 8 MB (16 MB total in
bank 1)
8 MB (16 MB total in
bank 0)
32 MB 16 MB (32 MB total in
bank 1)
Empty
64 MB 16 MB (32 MB total in
bank 1)
16 MB (32 MB total in
bank 0)
64 MB 32 MB (64 MB total in
bank 1)
Empty
128 MB 32 MB (64 MB total in
bank 1)
32 MB (64 MB total in
bank 0)
To install SIMMs, do the following procedure:
1. Holding the SIMM only by the edges, remove it from its antistatic package.
2. Position the SIMM at about a 45° angle relative to the system board. Make sure the
small notch in the middle of the bottom edge of the SIMM aligns with the notch in
the SIMM socket.
3. Insert the bottom edge of the SIMM into the SIMM socket and make sure it is seated
firmly.
4. When the SIMM seats correctly, hold it at each end and gently push the top edge
towards the retaining clips of the connector until the SIMM snaps into place (Figure
6). If the SIMM does not install correctly, gently spread the retaining clips just
enough so that you can pull away the top edge of the SIMM and try again.