User guide

Grounding Guidelines:
For best results, use a good quality earth ground, such as
metallic water piping or a driven ground, to ensure a good
connection to earth ground and good noise suppression.
If the ow sensor is installed in metallic piping, for optimum
connection clamp wire to the piping a short distance to one
side of the ow sensor using an electrical grounding clamp.
Connect the wire to the earth ground and to one of the housing
screws.
For Non-Metallic Pipe: Connect one to the housing screws by
wire to a good earth ground, such as metalic water piping or a
rod driven into the ground.
EX meters are usually unaffected by moderate levels of electri-
cal noise. In some applications performance may be improved
by taking the following steps:
• Use shielded twisted pair cable (Belden 8723 or
equivalent above ground or Alpha 35482 or
equivalent burial).
• Clamp a ferrite bead (Steward 28A2029-OAO or
equivalent) on meter signal/power wire within 3/4”
of the meter strain relief (tape or tie wrap in place if
necessary). See diagram below.
• IMPORTANT - Connect the cable shield ground
wire to ground, ONLY at power supply end of cable.
General Electrical Guidelines:
Whenever possible avoid running control cables in
the same conduit with or bundled with AC power.
Using shielded cable, be sure to connect shield to
ground at power supply end of the cable. Do not
connect other end of shield.
Avoid routing ow sensor cables in close proximity to
a variable frequency drive.
Recommended power and output wiring is shielded
twisted pair 18-22 AWG control cable.
Recommended voltage is 12-24 Vdc. Note that
unregulated power supplies can vary from nameplate
voltage by a considerable amount, especially with AC
line voltage uctuation. Therefore 24V power supplies
must be regulated.
See the Connections diagrams on the following pages for the
appropriate terminals.
Power: A 12 - 24 Vdc power supply capable of at least 250
mA current output is needed.
Output: The standard output is pulses with ow in the forward
direction (Reverse ow output is optional [-15] ). Electrically
it is an open collector opto isolated switch. The output is not
internally powered.
Note: This output is limited to 6 mA at 30 Vdc maximum.
Page 8
ELECTRICAL CONNECTIONS
GROUNDING DIAGRAM
Housing Screw
Earth
Ground
Grounding Clamp
PLACE FERRITE BEAD HERE
Metallic Pipe
Caution: The EX100/200 has a strong start
and run current. When using solar panels
and VRSLA batteries as a power source,
use caution to insure the EX-series sensor
has the -50 Low-power Option and that all Seamet-
rics products on the power circuit receive sufcient
voltage and current under all conditions. Failure to
do so will lead to unreliable operation and possible
damage to the unit/s. Please reference the technical
bulletin, ‘Solar and Battery-Power Guildlines’ avail-
able on our website: www.seametrics.com