TROUBLESHOOTING
Problem
Probable Causes Try...
No Display
Flow rate always reads “0”
Flow rate incorrect
Check for 110 Vac
Test fuse, replace if bad
Check ribbon cable connections
Reverse ow connections
Install ground wire
Install meter in vertical position
Use next smaller ow meter
Check connections on display board
Select another ow meter
Check for proper grounding
Select another ow meter
Install meter in vertical position
No power
Blown fuse
Loose ribbon cable
Reversed ow direction
Missing ground wire
Empty pipe
Flow rate below minimum
Loose wiring or incorrect wiring
Fluid conductivity <20 microSiemens/cm
Missing or incorrect ground wire
Fluid conductivity <20 microSiemens/cm
Empty pipe