Service manual

Latest products and information available at www.sealite.com.au
9
Flash Codes
SEALITE® code reference is listed by number of flashes
For the latest version of this document, check:
http://www.sealite.com.au
E-mail: info@sealite.com.au
Symbols
FL Flash followed by number Eg. FL 1 S, one flash every second
F Fixed
Q Quick flash
VQ Very quick flash
OC Occulting; greater period on than off
ISO Isophase; equal period on and off
LFL Long flash long
MO Morse code ( ) contains letter
For example, VQ (6) + LFL 10 S means 6 very quick flashes followed by a long flash, during a 10-
second interval.
The amount of power your lantern draws through the night depends on the duty cycle, i.e. the amount
of time on as a proportion to the timing cycle. For example, 0.5 seconds on and 4.5 seconds off
equals a 10% duty cycle.
It is best to operate at the lowest duty cycle appropriate to the actual needs of the application.
Please note, Sealite models will retain full autonomy in normal operating conditions with duty-cycles
up to approximately 30%. In applications whereby duty cycles exceed this limit, a reduction in lantern
intensity is recommended. Please contact a Sealite consultant if assistance is required.
Recommended Rhythm for Flashing Light - IALA Regions A and B
MARK DESCRIPTION RHYTHM
Port Hand & Starboard Marks:
Any, other than Composite Group Flashing (2+1)
Preferred Channel Starboard:
Composite Group Flashing (2+1)
Preferred Channel Port:
Composite Group Flashing (2+1)
North Cardinal Mark:
Very quick or quick
East Cardinal Mark:
Very quick (3) every 5 seconds or quick (3) every 10 seconds
South Cardinal Mark:
Very quick (6) + long flash every 10 seconds or quick (6) + long flash every 15 seconds
West Cardinal Mark:
Very quick (9) every 10 seconds or quick (9) every 15 seconds
Isolated Danger Mark:
Group flashing (2)
Safe Water Mark:
Isophase, occulting, one long flash every 10 seconds or Morse Code “A”
Special Marks:
Any, other than those described for Cardinal, Isolated Danger or Safe Water Marks