Intensity/power settings on Sealite lanterns operate via DIP switches, located near the rotary switches
on the asher unit. The intensity/power settings may be used to reduce the power consumption and
intensity of the lantern. Setting the lantern to 25% intensity will reduce the power consumption to 25%
of the normal 100% setting and the range by 25%. This setting may be used to adjust the current draw
of the light to local sunlight conditions.
The following diagrams indicate intensity/power settings:-
If the number of Full Sunlight hours is less than 2.5-3.0 hours, please consider reducing the intensity
(Power) or reducing the Duty Cycle.
Automatic Intensity Reduction for Fixed-On Character
When the ash code is congured to 00 or ‘Steady On’, the maximum intensity is set to 50%. If a
higher intensity is previously set when the lamp is on, the intensity will automatically fall to the 50%
setting when ash code 00 is congured.
The intensity settings available for lamps with a ash code set to 00 are 25% and 50%. The lamp
will ash an error condition if an intensity setting greater than 50% is selected with the IR Remote
Control.
If the ash code is changed from 00 to another value, the maximum allowable intensity reverts back
to 100%.
100%
1 2
ON
75%
1 2
ON
50%
1 2
ON
25%
1 2
ON
Intensity
Setting
Power White
cd
Green
cd
Red
cd
Yellow
cd
100% 120mA 176 88 121 95
75% 94mA 132 66 90 71
50% 64mA 88 44 60 48
25% 35mA 44 22 30 24
Selecting an Intensity/Power Setting
SL07, SLC310 & SLC410 Models
Model
Total power
used per night
(mAh)
Solar Panel
Charge (mA)
Number of full sunlight hours
required to break even
(the amount of time it will take for the solar to
replace what the light took out overnight)
SL07 Not Applicable
SLC310 / 277 =
SLC410 / 435 =