User Manual
W H L H I N S T R U C T I O N M A N U A L
13
3. Place a new element on top of the PTFE adhesive by fitting one eyelet of the heating element on
one mounting spring followed by the other mounting spring. Using a screwdriver to flex the
mounting spring inward will ease the placement of the element on the mounting spring. Check
the element to ensure it is tight and intact.
4. Cut off any worn out PTFE cover. Ease out enough footage of PTFE cover to cover the heating
element and extend to the front of the PTFE cover plate.
5. Tighten the screws to affix the PTFE cover plate.
6. If a whole roll of PTFE cover needs to be replaced, loosen the multi-star knob (Figure 12, Item
#47) found on the plate for PTFE (Figure 12, Item #48) and remove the PTFE roller (Figure 12,
Item #6). Tape one end of the PTFE cover to the rod and roll up the entire piece. Position the
PTFE cover and rod using the plate for PTFE. Ease out enough footage of PTFE cover to cover
the heating element and extend to the front of the PTFE cover plate.
Removing and Replacing Cutter Blades (HC models only)
1. Remove the cutting blade bracket from the silicone bracket. Remove the screw, washers and
spacer from the silicone bracket. Slide the cutting bracket out.
Figure 8. Unscrew the silicone bracket and remove screw, washer
and spacers.
Figure 9. Slide the cutting bracket out.
2. Remove the cutter protector and carefully remove the old blade.
The blade
found on the Long Hand sealer with cutter is very sharp. Use extreme caution when
handling or changing the blade.