Installing New Replacement Parts.
1. Remove the backing of the liner found on the PTFE adhesive.
2. Apply it to the sealer’s sealing platform. The PTFE adhesive must always extend past the sealing
platform by approximately ¼” to ½” on both ends. Bend down the excess on both ends. (The
PTFE adhesive acts a barrier between the metal body and the heating element. Never allow the
heating element to come in direct contact with the sealer’s body because it will damage the timer.)
3. Place a new element on top of the PTFE adhesive by fitting one eyelet of the heating element on
one mounting spring followed by the other mounting spring. Using a screwdriver to flex the
mounting spring inward will ease the placement of the element on the mounting spring. Check
the elements to ensure it is tight and intact.
4. Cut off any worn out PTFE cover. Ease out enough footage of PTFE cover to cover the heating
element and extend to the front of the PTFE cover plate.
5. Tighten the screws to affix the PTFE cover plate.
6. If a whole roll of PTFE cover needs to be replaced, loosen the multi-star knob (Figure 10, Item
#15) found on the plate for PTFE (Figure 10, Item #14) and remove the PTFE cover roller
(Figure 10, Item #18). Tape one end of the PTFE cover to the rod and roll up the entire piece.
Position the PTFE cover and rod using the plate for PTFE. Ease out enough footage of PTFE
cover to cover the heating element and extend to the front of the PTFE cover plate.
Figure 7. Loosen multi-star knob to remove the PTFE roller.