MAINTENANCEREPLACE BLOWER MOTOR
6. Remove Bolt Holding Blower wheel to Blower Motor.
Note: This housing should be tested outside the tunnel to
assure that it works. Reassemble in the same manner as
disassembled. (If force is necessary, apply it between the
motor and the blower wheel hub.) Now remove the
motor mount bolts and remove/replace motor.
Reassemble new motor and blower wheel housing.