User Manual

Sealer Sales Page 34
ST-1808-28 Tunnel Service Manual
MAINTENANCE
MAINTENANCE
To aid in maintaining the high reliability of this shrink tunnel,
the following maintenance should be provided.
DISCONNECT ALL POWER BEFORE MAKING ANY REPAIRS.
IF UNSURE OF ANYTHING, CONTACT
A QUALIFIED SERVICE TECHNICIAN
A. The conveyor chains should be lubricated once a month with a
high temperature oil. The lubricant should be applied with a
brush or sprayed while the conveyor is slowly running.
B. The silicone covering on the tunnel rollers should be inspected
regularly to assure that no scrap pieces of film are wrapped
around the rollers to cause sticking of packages. To clean, run
conveyor until the affected rollers are within the heated
chamber, thus heating the film residue to soften the film, then
advance the conveyor to stop the rollers outside the heat
chamber for cleaning. Make sure the conveyor is stopped
before putting your hands or anything else in the conveyor
area. If necessary to remove the film residue, use a dull, blunt-
edged tool. Do not use any sharp instruments, as nicking the
silicone may result in having to replace the roller covering.
To replace silicone covering on the roller proceed as follows: