User Manual
Sealer Sales Page 23
ST-1808-28 Tunnel Service Manual
TEMPERATURE CONTROL ADJUSTMENT
Temperature Control Adjustment
PV = Present Value
SV = Set Value
On the above temperature controller the set value is 300
degrees and its present temperature is at 298 degrees.
To Adjust Temperature Up or Down:
First you must press the arrow key that points left (). When
pressing this key the set value temperature will flash first in the ones
column. While flashing, you may adjust temperature by now
pressing the arrow keys either up or down () to the desired
temperature in the ones column. Repeat this procedure by pressing
the left arrow () to move flashing light to the tens column or the
hundreds column and adjust up or down to desired temperature.
Once you have adjusted to desired temperature press the set key
and the temperature will now become your new set value (SV).