User Manual
F R M - 1 1 2 0 C I N S T R U C T I O N M A N U A L
11
Operation
Figure 7. Control Panel of FRM-1120C
1. Our machines are equipped with a three-prong grounded plug. Make sure the plug is well-
connected in the socket to ensure safe operation.
2. Make sure the circuit breaker is in the “ON” position. (Levers pointing up)
3. Turn Power, Heat (Seal), Fan, and Printer switches to the “On” position. Belts and conveyor
will begin to move simultaneously.
4. Adjust the conveyor speed.
5. Adjust the temperature controller to the temperature desired to seal your material. Temperature
settings will vary based on bag material and thickness. If you are unsure what temperature setting
to use, we recommend starting at a low temperature (150ºC) and gradually increase to a
temperature that will seal your material. We highly discourage sealing material at a temperature
above 200ºC. Please note: Temperature will be in Celsius, not Fahrenheit. The
temperature controller cannot be displayed in Fahrenheit.
The PV value is the actual temperature and the SV value is the desired temperature setting. The
SV value can be viewed by pressing the button.
Figure 8. FRM-1120C Temperature Controller