SDS
Page 3
5.
FIRE
-
FIGHTING MEASURES
Suitable Extinguishing Media
Carbon Dioxide (CO
2
). Dry Chemical. Dry Sand. Alcohol-resistant Foam.
Unsuitable Extinguishing Media The use of water spray when fighting fire may be inefficient.
Specific Hazards Arising from the Chemical
No information available
Explosion Data
Sensitivity to Mechanical Impact None
Sensitivity to Static Discharge None
Protective Equipment and Precautions for Firefighters
As in any fire, wear self-contained breathing apparatus pressure- demand MSHA/NIOSH (approved or equivalent) and full protective
gear.
6.
ACCIDENTAL RELEASE MEASURES
Personal Precautions, Protective Equipment, and Emergency Procedures
Personal Precautions: Use personal protective equipment as required. Ensure adequate ventilation, especially in
confined areas.
Environmental Precautions
Environmental Precautions: See Section 12 for additional Ecological Information. Prevent product from entering
waterways, sewers, basements or confined areas. Do not flush into surface water or
sanitary sewer system.
Methods and Materials for Containment and Cleaning Up
Methods for Containment: Prevent further leakage or spillage if safe to do so.
Methods for Cleaning Up: Cover liquid spill with sand, earth or other non-combustible absorbent material. Use
personal protective equipment as required. Dam up. Take up mechanically, placing in
appropriate containers for disposal. Clean contaminated surface thoroughly.
7.
HANDLING AND STORAGE
Precautions for Safe Handling
Handling: Handle in accordance with good industrial hygiene and safety practice. Avoid contact with
skin, eyes, and clothing. Wear personal protective equipment as required. Do not breathe
dust/fume/gas/mist/vapors/spray. Do not eat, drink, or smoke when using this product.
Wash thoroughly after handling.
Conditions for Safe Storage, Including Any Incompatibilities
Storage: Keep container tightly closed in a dry and well-ventilated place. Keep out of the reach of
children.
Incompatible Products: Strong oxidizing agents. Strong acids. Strong Bases.
8.
EXPOSURE CONTROLS / PERSONAL PROTECTION
Control Parameters
Exposure Guidelines
Chemical
Name
ACGIH TLV
OSHA PEL
NIOSH IDLH
Titanium Dioxide
13463-67-7
TWA 10 mg/m³ TWA 15 mg/m³ total dust IDHL: 5000 mg/m³
Appropriate Engineering Controls
Engineering Measures: Showers
Eyewash Stations
Ventilation Systems
Individual Protection Measures, such as Personal Protective Equipment
Eye/Face Protection: Wear safety glasses with side shields (or goggles).
Skin and Body Protection: Wear protective gloves and protective clothing.
Respiratory Protection: If exposure limits are exceeded or irritation is experienced, NIOSH/MSHA approved
respiratory protection should be worn. Positive-pressure supplied air respirators may be
required for high airborne contaminant concentrations. Respiratory protection must be
provided in accordance with current local regulations.
Hygiene Measures: Handle in accordance with good industrial hygiene and safety practice.