Owner manual
9
Dometic Freshwater Tank Monitor Specifications
5.3 Dimensions
(g.
2
, page 2)
Ref. Dimension
A 83 mm / 3.25 in.
B 83 mm / 3.25 in.
C 51 mm / 2 in. clearance behind wall
D 10mm/0.38in.
Ref. Dimension
E 111 mm / 4.375 in.
F 25mm/1.0in.(ifapplicable)
G 527mm/20.75in.
H 69 mm / 2.75 in.
5.4 Approvals
ISO8846;EMCDirective2004/108/EC;CEapprovedforelectromagneticcompatibility
6 Installation
6.1 Tank Monitor Panel (g.
3
A, page 2)
Caution!
DonotinstallDTMF04panelinanatmospherewithpotentiallyammableorexplosive
vapors.
1. Select panel location away from direct contact with water
and oil.
2. Conrm clearance for wire connections behind wall, hull
liner or bulkhead.
3. Usingcontrolpaneltemplate(g.
6
, page 5), cut out panel
access hole (E, F) and drill fastener holes (G).
4. With electrical power off, route 18-gauge stranded copper
wire from power source, through circuit breaker or fuse (not
provided), to panel location. Route additional wire accord-
ing to diagram (g.
4
,page3–seewiringdiagramkey
below), depending on your application, to panel location.
Make sure wires extend out through access hole.
5. Make proper wiring connections to wires extending from
bottom of circuit panel (g.
3
A 2, page 3).
6. Remove panel cover (g.
3
A 1, page 3) from circuit panel/
mounting frame (A 2), if necessary, by carefully pulling them
apart.
7. Install mounting frame to wall with four fasteners (g.
3
A
3).
8. Pushpanelcoverontomountingframeuntilitlocks.
6.2 “Empty Tank” Shut-down Relay
(optional accessory) (g.
1
4, page 2)
1. At step 4 (above), route and connect 14-gauge stranded copper wires according to wiring diagram
(g.
4
, page 3) and wiring diagram key (see section 6.4).
2. Remove circuit panel housing from circuit panel (g.
1
5, page 2), and insert “Empty Tank” shut-
down relay into receptacle on back of circuit panel. Re-attach circuit panel housing.
DTMF04 Panel Template
Dimensions
(g.
6
, page 5)
Ref. Dimension
A 83 mm / 3.25 in.
B 83 mm / 3.25 in.
C 67 mm / 2.63 in.
D 67 mm / 2.63 in.
E 55 mm / 2.16 in.
F 68 mm / 2.69 in.
G 2mm/0.10in.dia.
H Cut-out area.
Allow 51 mm / 2 in.
clearance behind
wall.