Owner's manual

7
1. Route18-gaugestrandedcopperwirefromDCGroundsourceto
probe assembly.
2. Usingquick-disconnectterminals,makeproperwiringconnections
fromDCGroundsourceandindicatorpaneltoprobeassemblywires.
Refer to wiring diagram (g.
5
, page 6).
3. Selectprobeassemblylocationawayfromothertankttings.Drill
1.25-in.(32mm)dia.holeintopoftank.
4. Placeprobeassemblyintocenterofhole.Markfourfastenerlocations
at corners. Remove probe assembly from hole.
5. Drillfastenerholeswith1/8-in.(3mm)drillbit.
6. Withprobeassemblyremovedfromtank,turnonelectricalpowerto
system.Moveblackoatupanddowntoassureproperoperationof
oatandindicatorlight.Redindicatorlightshouldilluminatewhen
oatispushedup.Aftersuccessfultest,turnoffelectricalpowerand
disconnectwiresatquick-connectterminals.
7. Placeprobeassemblyintoholeintopofholdingtank.Usefour#8
fasteners(provided)tosecureprobeassemblyintoholdingtank
(g.
4
, page 2). Re-connect wires and turn on electrical power.
6.2 Probe Assembly (g.
4
, page 2)
Caution!
Do not use probe assembly in fuel tank. Never install the probe
assemblywithoatswitchintankthatcontainsanythingother
than wastewater, gray water or fresh water.
Note
Forinstallationinsailboats:Locateprobeassemblyonathwart-
shipscenterlineoftanktoassureaccuracywhenheeled.
DTM01 Tank Monitor Installation