6 Installation
1. Select panel location away from direct contact with water and oil.
2. Conrm clearance for wire connections behind wall, hull liner or
bulkhead.
3. Usingindicatorpaneltemplate(g.
6
, p. 9), cut out panel access
hole and drill fastener holes.
4. With electrical power off, route 18-gauge stranded copper wire from
powersource,through0.5ampfuse(notprovided),topanellocation.
Route18-gaugestrandedcopperwirefromholdingtankprobe
assemblytopanellocation.Makesurewiresextendoutthrough
access hole (g.
3
2, p. 2).
5. Install mounting frame (g.
3
1, p. 2) with four #6 fasteners (provided).
6. Makeproper12or24VDCwiringconnectionstoindicatorpanel.
Refer to wiring diagram (g.
5
, below).
7. Pushindicatorpanelontomountingframeuntilitlocksintoplace.
6.1 Indicator Panel (g.
3
, page 2)
Caution!
Donotinstallindicatorpanelinanatmospherewithpotentially
ammableorexplosivevapors.