Owner manual
8
Dometic Tank Discharge ControlInstallation
7.1 OPTION 1: DTD01 discharge control panel only
(g.4,page3)
1. When boat is in unrestricted waters and pump-out is desired, insert key into switch and turn to
momentary“Start”position(1).
2. Allowkeytoreboundto“PumpOn”position(2).Greenlightindicatesthatpumpisrunning.
3. Whenpump-outiscomplete,turnkeyto“Off”position(3)andremovekeyfromswitch.
4
7 Operation
6.3 Key to DTD01-DTM04 system wiring (g.7,page4)
Ref. Description
A DTD01controlpanel
B Dischargepump
C DTM04indicatorpanel
D Wastewater tank
E 12or24VDC
F VDCground
G Dischargepumpcircuitbreakerorfuse
H 12VDC
I 24VDC
J 1-amp circuit breaker or fuse
K Toilet system circuit breaker or fuse
7
Ref. Description
L +VDCtoelectrictoiletsystem
M Full level probe
N Mid level probe
O Low/Empty level probe
P Red
Q Black
R Brown
S Green
T Blue
U Yellow
V Orange
6.2 Key to DTD01 - discharge pump system wiring (g.5,page3)
Ref. Description
A DTD01controlpanel
B Dischargepump
C 12or24VDC
D VDCground
5
Ref. Description
E Dischargepumpcircuitbreakerorfuse
F Red
G Black
H Brown
1.Use14gaugeorlargerdiameterstandardcopperwire.
2. Maximum discharge pump circuit breaker or fuse rating: 20 amps.
1. Heavy line indicates 14 gauge or larger stranded copper wire is required.
2. Other wire can be 18 gauge stranded copper wire or larger.