Owner manual
7
6 Installation
1. Select panel location away from direct contact with
water and oil.
2. Conrm clearance for wire connections behind wall,
hull liner or bulkhead.
3. Usingcontrolpaneltemplate(g.8,page11),cutout
panelaccesshole(E,F)anddrillfastenerholes(G).
4. With electrical power off, route 14-gauge stranded copper
wire from power source, through discharge pump circuit
breakerorfuse(notprovided),topanellocation.Route
additional wire according to diagram on page 3 or 4
(seewiringdiagramkeysbelow),dependingonyour
application, to panel location. Make sure wires extend
out through access hole.
5. Make proper wiring connections to wires extending from
bottomofcircuitassembly(g.24,page2).
6. Removepanelcover(g.21,page2)frommounting
frame(2)bycarefullypullingthemapart.Makesurewires
betweenkeyswitch(3)andcircuitassembly(4)remain
attached.(Keypin1–red;pin2–brown;pin7–blue.)
7. Installmountingframetowallwithfourfasteners(5).
8. Tuck key switch wires into circuit assembly housing,
and push panel cover onto mounting frame until it
locks into place.
9. Turn on electrical power.
6.1 Tank Discharge Control Panel (g.2,page2)
Control Panel Template
Dimensions
(g.8,page11)
2
Dometic Tank Discharge Control Specifications
Caution!
Do not install DTD control panel in an atmosphere with potentially flammable or
explosive vapors.
Ref. Dimension
A 83mm(3.25in.)
B 83mm(3.25in.)
C 67mm(2.63in.)
D 67mm(2.63in.)
E 55mm(2.16in.)
F 68mm(2.69in.)
G 2mm(0.10in.)dia.
H Cut-out area.
Allow51mm(2in.)
clearance behind wall.
8
8
2
2
ISO8846;EMCDirective2004/108/EC
5.4 Approvals
5.3 Dimensions
(g.3,page2)
Ref. Dimension
A 83mm(3.25in.)
B 83mm(3.25in.)
3
Ref. Dimension
C 51mm(2in.)clearancebehindwall
D 10mm(0.38in.)
Maximumrelayratingfor12or24VDCdischargepump:20amps.
FloatSwitchRating:20wattswithresistiveload(whenusedwithDTM04system).