Owner manual
6
Dometic Tank Discharge ControlIntended use
System Voltage Pump Off (amp) Pump On (amp)
12VDC 0 0.16
24VDC 0 0.095
4 Components
Items in fig.
1 page 2
Description Item Number(Europe/NorthAmerica)
1 Replacement key 860003853110362 / 385311036
2 Switch assembly 860003853116104 / 385311610
3 Panel cover 860003853116112 / 385311611
4 #6 fastener 860003853116120 / 385311612
5 Mounting frame 860003853116138 / 385311613
6 Circuit assembly
860003853116146/385311614–12VDC
860003853116153/385311615–24VDC
7 Circuit assembly housing 860003853116161 / 385311616
1
5 Specifications
5.1 Materials
3.3 Features
Secure discharge pump control. Key-operated switch provides convenient means to secure
discharge pump operation without use of padlocks or other mechanical fasteners.
Helps prevent pump burn-out. Activatedpanellightindicateswhendischargepumpisoperating.
Reminds operator to shut off pump when tank discharge is complete.
Automatic pump shut-off with DTM04 tank monitor system. Dischargepumpstopswhentanklevel
dropsbelow“Empty”levelprobe(g.64,page4).
Simplifies plumbing system. Eliminates wye valves, seacocks and vented loops of multiple
toilet systems.
5.2 Electrical Current Draw(panelonly)
Panel frame and mounting frame:ABSPanel surface: Polycarbonate resin
Circuit assembly housing: High-density polyethylene
6
Specications subject to change without notice.
Caution!
Operator must know local regulations for emptying a holding tank.