User guide
3
NEW INSTALLATION
1. Plan ush switch location so cable can reach toilet
base circuit board. Be sure cable cannot get wet.
2. Using correct Dometic, Vimar or Gewiss panel
template (see Section 5), mark center access and
fastener holes. Cut out square access hole to size
(g.
4
). Make sure there is at least 2 inches
(51 mm) of clearance behind wall surface.
3. Route ush switch cable from wall access hole to
oor access hole at toilet base, leaving about
12 inches (305 mm) of extra cable at toilet.
4. Attach cable to back of ush switch circuit board
(g.
4
), then fasten ush switch bracket
to wall with supplied screws (g.
5
).
5. Snap Dometic, Vimar or Gewiss cover plate onto
bracket (g.
5
) at proper connection points (see
Section 6, back page).
6. WITH ELECTRICAL POWER OFF, connect wiring
cable from the ush switch to the RJ45 connector
on the circuit board of the toilet base (g.
6
).
6
4
Caution!
If replacing a previous electronic ush
switch, WITH ELECTRICAL POWER OFF,
be sure to disconnect wiring from old
switch before installing new ush switch.
5
VFS, VFP models for VacuFlush toilets DFS, DFP models for other SeaLand toilets
1.2 Flush switch panel