Installation Instruction Manual

11
SeaLand 9300-9400 Series RushFlush Toilets Installation
19
5.3 Toilet with through-the-wall connections
1. To install wiring and plumbing connections through the wall,
determine the primary centerline location as described in
Section 5.2, steps 2 and 3.
2. Mark horizontal primary centerline for plumbing and wiring
access holes on wall according to g.
19
. Mark secondary
centerline for lower bowl water line 3 in. (76 mm) to left of
primary centerline. Mark hole locations as indicated.
3. Drill two 1-1/2 in. (38 mm) dia. holes for water supply lines
and wiring, and drill 2.25 in. (57 mm) dia. hole for discharge
plumbing (g.
19
).
4. Follow toilet installation instructions beginning at Section 5.2,
step 15. For lower bowl water line, install an elbow tting (not
provided) so that 1 in. ID exible water line can loop upward
and back down to inlet at toilet base (g.
3
7, p. 2).
5. Before securing toilet to oor with lag bolts (step 25), be sure
to drill 3/16 in. pilot holes.
5.4 9300 series toilet system status panel
(optional accessory)
1. Plan status panel location so that electrical connections can
be made between toilet and status panel with wiring cable
provided. Be sure cable and connections cannot get wet.
2. Use Dometic wall switch template to mark location of
fastener and access holes for status panel. Drill 1 in. (25 mm)
wiring access hole, then fasten panel bracket to wall
(g.
20
).
3. Attach cable (provided with status panel) to status panel’s
RJ45 connector, then route other end of cable through wall
access hole to oor access hole at toilet base.
4. Snap the status panel cover onto the panel bracket (g.
20
).
5. WITH ELECTRICAL POWER OFF, connect cable from the
status panel to the toilet control module (g.
21
). To attach
RJ45 connector, remove control module from back of toilet
(locking fabric strips will come apart), route cable up through
toilet plumbing lines to connect to module, then re-attach
control module to back of toilet.
6. After all toilet wiring connections are made, turn on
electrical power to toilet system. A steady green “Power On”
light indicates that electrical power to the toilet is activated.
20
21
3 in.
4 in.
1.5 in.
1.5 in. dia.
2.25 in. dia.
1.5 in. dia.
Lower bowl
water line
Upper rim water line,
electrical wires
Discharge
outlet