CONVERSION TABLE
Wire – AWG to mm
2
Feet to Meters
AWG 14 12 10 Ft 10 15 20 30 50
mm
2
2.5 4.0 6.0 M 3.1 4.6 6.1 9.2 15.2
Wire size per length of run* 0-15 ft. 16-30 ft. 31-50 ft.
12 volts DC #14 #12 #10
* Distance from circuit breaker to electronic control module.
WIRE SIZING CHART
When installing a SeaLand macerator toilet in a recreation vehicle, please use the following wiring
information. Refer to MasterFlush toilet parts list for complete macerator toilet wiring diagram.
Installation notes
Each toilet must have its own circuit breaker or fuse.
Wire sizes must be appropriate for the installation. All other installation factors must be in
accordance with ISO electrical standards.
Always use stranded copper wire (preferably tinned).
Always use crimp-type wire connections. Do not use wire nuts (they corrode).
Warning!
Hazard of Shock or Fire: Always use recommended fuse, circuit breaker and wire size.
Failure to do so can cause the loss of property and life.