Installation Manual

15
CONVERSION TABLE
Wire – AWG to mm
2
Feet to Meters
AWG 14 12 10 Ft 10 15 20 30 50
mm
2
2.5 4.0 6.0 M 3.1 4.6 6.1 9.2 15.2
Wire size per length of run* 0-15 ft. 16-30 ft. 31-50 ft.
12voltsDC #14 #12 #10
*Distancefromcircuitbreakertoelectroniccontrolmodule.
WIRE SIZING CHART
WheninstallingaDometicmaceratortoiletinarecreationvehicle,pleaseusethefollowingwiring
information.
Warning – recreation vehicle applications
The following must be read and understood before installing, servicing and/or operating this product
on a recreation vehicle. Modification of this product may result in property damage.
DometicrecommendsthataqualiedRVtechnicianorelectricianinstallorservicethisproductwith
regardtoallapplicablecodesandregulations.Equipmentdamage,personalinjuryordeathcouldresult
fromimproperinstallation.DOMETICACCEPTSNORESPONSIBILITYORLIABILITYFORDAMAGETO
EQUIPMENT,ORPERSONALINJURYORDEATHTHATMAYRESULTFROMIMPROPERINSTALLA-
TION,SERVICEOROPERATIONOFTHISPRODUCT.
Installation notes
• Eachtoiletmusthaveitsowncircuitbreakerorfuse.
• Wiresizesmustbeappropriatefortheinstallation.Allotherinstallationfactorsmustbeinaccordance
withISOelectricalstandards.
• Alwaysusestrandedcopperwire(preferablytinned).
• Alwaysusecrimp-typewireconnections.Donotusewirenuts(theycorrode).
Warning!
Hazard of Shock or Fire: Always use recommended fuse, circuit breaker and wire size.
Failure to do so can cause the loss of property and life.
Dometic 8700 Series MasterFlush Toilet RV Installation Appendix
Wiring / Electronic Control Module Connections