Manual
7
Dometic Gravity-Flush Toilet Installation
6 Installation
Note
Be sure foot pedal, when pressed, touches same at surface on which toilet is installed.
Note
Be sure to follow recommended installation requirements in section 4.2 of this manual.
6.1 Tools required
• pliers or adjustable wrench
• 7/16-in. / 11 mm wrench
6.2 Toilet installation
1. To replace an older toilet, turn off water supply to toilet. Remove and drain water supply line.
Remove toilet hold-down bolts/screws. Remove toilet from oor. Remove and discard old
oor ange seal and hold-down bolts. Verify center of oor ange is at least the recommended
rough-in distance from back wall (g.
3
A, p. 3) for your toilet model (see Rough-in dimensions
chart). Make sure top surface of oor ange is clean and free of any debris or sealant.
2. If installing a new oor ange, make certain that toilet mounting holes are located at the correct
angle (g.
3
D, p. 3). Floor ange must be secured to oor with a minimum of four screws
(8 is preferred). Insert two supplied T-bolts into slots in oor ange (g.
4
p. 3).
3. Verify that oor ange seal is installed on base of toilet (g.
5
A, p. 3). Carefully set toilet over
oor ange. Align holes in toilet base with T-bolts as toilet is lowered onto oor ange. Toilet
must be aligned so that outlet of base ts inside of oor ange outlet hole.
Note
Entire toilet base does not rest completely on oor yet. Floor seal must be compressed in
following steps.
4. Install oor mounting nuts and washers onto T-bolts. Carefully torque nuts to 30-40 inch-
pounds. DO NOT OVERTIGHTEN. Alternate between sides when tightening to prevent
distortion of base. When tight, base should be securely attached and at against oor.
Attach bolt covers onto nuts. (Fig.
5
B, p. 3)
5. If toilet is being installed in a shower stall, apply a bead of caulk around base of toilet to prevent
water seepage under base.
6. Connect water supply line and torque connection to 30-40 inch-pounds.
DO NOT OVERTIGHTEN. (Fig.
5
C, page 3)
7. Turn on water supply line. Flush toilet several times and check for leaks.