Owner`s manual
5
4
5
6
7
8
10
9
0
20
40
60
80
100
120
140
160
1
2
3
6500 XT BACK CONTROL PANEL
1. Air Pressure Gauge: Indicates the PSI reading
for the downward pressure of the top pull
roller. The standard setting for the normal
operation is 35-55 PSI.
2. Air Regulator Knob: Adjusts the downward
pressure of the top pull roller. Turn clockwise
to increase the pressure.
3. Roller Up/Down Switch (Rear, Top): Press
the switch up to raise the roller. Press the
switch down to lower the roller.
4. Reset Button: Press this button to reset the
material total usage counter to zero. Totalizer
Display must be showing to be able to zero out.
5. Ratemeter /Totalizer Button: Pressing this
button will toggle between the roller speed
readout or total material usage. Press this
button to track and display the total number of
feet or meters run in a given period, which can
help to monitor film usage. The total will be
stored even after the laminator is turned off,
and adds to the total whenever the bottom
main roller is turning. The corresponding LED
will be lit when the Totalizer is being used.
6. Ratemeter/Totalizer Readout: Displays the
rate of speed of the main rollers in either feet or
meters per minute, or displays the total number
of feet or meters run in a given period.
7. Top Rear Roller On/Off Button: Turns
On/Off the top rear roller heater. The
corresponding LED will be lit when the heater
is ON.
8. Top Rear Roller Temperature Increase
Button: Press this button once to view the
temperature set point. Press and hold the
button to raise the top rear roller temperature.
9. Top Rear Roller Temperature Readout: Displays both
the set and actual temperature of the top rear roller.
10. Top Rear Roller Temperature Decrease Button: Press
this button once to view the set point. Press and hold the
button to lower the top rear roller temperature.
Figure 1. 6500 XT Top Heat Back Control Panel