Specifications

36
Error Messages In
Temperature Display
Cause Solution
Reset Stand-by On/Off Switch
Contact Technical Service (See rear cover)
E3.0
Motor drive is overloaded
Check brake tension. Too much tension is
the primary cause of this error
Verify correct settings are being used for
rollers
Contact Technical Service (See rear cover)
E3.1
Main motor drive is getting no
encoder pulses
Check fuses F1 and F2 on main board
Contact Technical Service (See rear cover)
E3.2
Main motor does not stop Contact Technical Service (See rear cover)
E3.3
Motor appears shorted Contact Technical Service (See rear cover)
E3.4
Motor speed is not reasonable
for requested drive voltage
Check brake tension
Contact Technical Service (See rear cover)
E4.0
A power supply voltage is bad
Reset Stand-by On/Off Switch
Contact Technical Service (See rear cover)
E4.1
Software reset the system
Reset Stand-by On/Off Switch
Contact Technical Service (See rear cover)
E4.2
The hardware safety system
reset the system
Reset Stand-by On/Off Switch
Contact Technical Service (See rear cover)
E5.0
A thermal cutoff switch is open
or disconnected
Shut down and power off. Wait 30 minutes
for system to cool and reset power
Contact Technical Service (See rear cover)
E5.1
A thermocouple is open or
disconnected
Reset Stand-by On/Off Switch
Contact Technical Service (See rear cover)
E5.2
Measured temperature exceeds
the maximum temperature by
at least 25 degrees C for at
least one minute
Reset Stand-by On/Off Switch
Contact Technical Service (See rear cover)
E5.3
Measured temperature differs
from the setpoint temperature
by at least 25 degrees C for at
least 15 minutes or
appropriately longer time if
setpoint temperature has been
changed
Reset Stand-by On/Off Switch
Contact Technical Service (See rear cover)
CAUTION: If other error messages appear, contact Technical Service (see rear cover)