Specifications
11
FRONT CONTROL PANEL SYSTEM
1. Air Pressure Gauge: Indicates the PSI reading for the
downward pressure of the top main roller. The
standard setting for the normal operation is 35-55 PSI.
2. Air Regulator Knob: Adjusts the downward pressure of
the top roller. Turn clockwise to increase the pressure.
3. Roller Up/Down Switch (Front, Top): Press up to raise
the roller. Press down to lower the roller.
4. Cooling Fan On/Off Button: Turns On/Off the
cooling fan. The corresponding LED will be lit when
the fan is ON.
5. Reset Button: Press this button to reset the material
total usage counter to zero. Totalizer Display must be
showing to be able to zero out.
6. Ratemeter /Totalizer Button: Pressing this button will
toggle between the roller speed readout or total
material usage. Press this button to track and display
the total number of feet or meters run in a given
period, which can help to monitor film usage. The total
will be stored even after the laminator is turned off,
and adds to the total whenever the bottom main roller
is turning. The corresponding LED will be lit when the
totalizer is being used.
7. Ratemeter/Totalizer Readout: Displays the rate of
speed of the main rollers in either feet or meters per
minute, or displays the total number of feet or meters
run in a given period.
8. Top Roller Temperature Increase Button: Press this
button once to view the temperature set point. Press
and hold the button to raise the top roller temperature.
9. Top Roller Temperature Readout: Displays both the set
and actual temperature of the top roller.
10. Top Roller Temperature Decrease Button: Press this
button once to view the temperature set point. Press
and hold the button to lower the top roller
temperature.
11. Bottom Roller Temperature Increase Button: Press this
button once to view the temperature set point. Press
and hold the button to raise the bottom roller
temperature.
12. Bottom Roller Temperature Readout: Displays both
the set and actual temperature of the bottom roller.
13. Bottom Roller Temperature Decrease Button: Press
this button once to view the temperature set point.
Press and hold the button to lower the bottom roller
temperature.
14. Bottom Roller Temperature On/Off Button: Turns
On/Off the bottom roller heater. The corresponding
LED will be lit when the heater is ON.
15. Top Roller Temperature On/Off Button: Turns
On/Off the top roller heater. The corresponding LED
will be lit when the heater is ON.
16. Stand-by On/Off Switch: Press this switch up to turn
on the laminator. Press this switch down to put it on
Standby. In Standby, the laminator power is still on, but
all functions are disabled.
Figure 4: Front Control Panel System
0
2
4
6
8
1
1
1
1
2
3
4
5
7
6
10
9
16
11
15
12
8
13
14
1