Section 4. First aid measures
Protection of first-aiders
:
No action shall be taken involving any personal risk or without suitable training. If it is 
suspected that fumes are still present, the rescuer should wear an appropriate mask or 
self-contained breathing apparatus. It may be dangerous to the person providing aid to 
give mouth-to-mouth resuscitation. Wash contaminated clothing thoroughly with water 
before removing it, or wear gloves.
See toxicological information (Section 11)
Section 5. Fire-fighting measures
Promptly isolate the scene by removing all persons from the vicinity of the incident if 
there is a fire. No action shall be taken involving any personal risk or without suitable 
training. Move containers from fire area if this can be done without risk. Use water 
spray to keep fire-exposed containers cool.
Hazardous thermal 
decomposition products
Specific hazards arising 
from the chemical
Decomposition products may include the following materials:
carbon dioxide
carbon monoxide
halogenated compounds
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the 
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along 
the ground. Vapors may accumulate in low or confined areas or travel a considerable 
distance to a source of ignition and flash back.
Fire-fighters should wear appropriate protective equipment and self-contained breathing 
apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Special protective 
equipment for fire-fighters
Use dry chemical, 
CO₂,
 water spray (fog) or foam.
Extinguishing media
:
:
:
Do not use water jet.
Suitable extinguishing 
media
:
Unsuitable extinguishing 
media
:
Special protective actions 
for fire-fighters
:
Section 6. Accidental release measures
Environmental precautions
Personal precautions, protective equipment and emergency procedures
:
:
No action shall be taken involving any personal risk or without suitable training.
Evacuate surrounding areas. Keep unnecessary and unprotected personnel from 
entering. Do not touch or walk through spilled material. Shut off all ignition sources.
No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide 
adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Put 
on appropriate personal protective equipment.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains 
and sewers. Inform the relevant authorities if the product has caused environmental 
pollution (sewers, waterways, soil or air).
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and 
explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively,
or if water-insoluble, absorb with an inert dry material and place in an appropriate waste 
disposal container. Dispose of via a licensed waste disposal contractor.
Small spill
:
Methods and materials for containment and cleaning up
For non-emergency 
personnel
For emergency responders
:
If specialized clothing is required to deal with the spillage, take note of any information in 
Section 8 on suitable and unsuitable materials. See also the information in "For non-
emergency personnel".